Maintenance
Weekly Cleaning
In addition to the daily cleaning it is necessary to clean the air intakes on a weekly basis. Air intakes provide necessary cooling air
to the internal components. They are generally located on the rear and sides of the equipment.
Monthly Cleaning
Market Forge recommends using Optipure DSP descaling powder to clean your steamer on a monthly basis or whenever
necessary.
Optipure DSP is an acid based descaler that is effective in dissolving and removing build up caused by hard water.
DSP is a non-hazardous, biodegradable citrus based powder that when mixed with water becomes a powerful lime
scale remover. For additional information contact Optipure at 800-535-5035.
1. Make sure the steamer is off and cool.
2. Drain water from the cooking cavity and wipe away any food debris.
3. Make sure the drain is plugged.
4. Pour one pound of Optipure DSP per steamer into the bottom of the cooking cavity.
One pound is equal to 16 scoops (measuring scoop included), or one-half of a 2 lb. jar of descaling powder.
5. Set the control to Steam (#2) position. This will automatically fill the unit with water.
6. Allow the unit to reach steaming temperature and continue steaming for one hour.
7. Turn the unit off, and allow it to cool for one hour.
8. Drain the unit, and rinse the entire cooking chamber thoroughly.
9. If the unit is heavily scaled, it may be necessary to repeat the process.