Installation; Mechanical Design Of Devices - Pepperl+Fuchs Barcon PPC Operating Instructions Manual

Pressure transmitter
Table of Contents

Advertisement

2

Installation

This section describes:
the mechanical design of Barcon,
the mechanical installation of Barcon with and without diaphragm seal,
the electrical connection.
2.1

Mechanical design of devices

Mechanical design of Barcon with stainless steel housing
lid (standard)
lid with lid lock
(Ex-version, only)
measuring cells
measuring range
high
pressure
0 bar ... 0,1 bar
0 bar ... 0,4 bar
0 bar ...
1 bar
0 bar ...
4 bar
0 bar ... 10 bar
0 bar ... 40 bar
-0,1 bar ... +0,1 bar
-0,4 bar ... +0,4 bar
-1bar ...
+1 bar
-1bar ...
+4 bar
-1bar ... +10 bar
screws 3 x 10
(included)
screws 3 x 8
electronics
holder
central
mount
housing
F15
(stainless steel)
negative
absolute
pressure
high press.
Barcon LHC/PPC (HART)
Contents
lid with sight glass: glass (Ex i)
lid with lid lock and
sight glass: glass
lid with sight glass: polycarbonate
display module complete
with retaining ring
retaining ring separate
electronic module HART
programmed with sensor parameters
(When ordering, please state the serial number
of the instrument (given on the nameplate).)
profile seal 64.2 x 72.7 x 5
(set 5 pieces)
cable entry
½ NPT
M20 x 1,5
M12 x 1 plug
Harting plug
flat seal silicon 40 x 43 x 1
(set of 5, but included with
the sensor)
Installation
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Barcon lhc

Table of Contents