Introduction - Pepperl+Fuchs Barcon PPC Operating Instructions Manual

Pressure transmitter
Table of Contents

Advertisement

Barcon LHC/PPC (HART)

Introduction

Application
Operating principle
Measuring system
8
1
Introduction
The Barcon PPC and the Barcon LHC pressure transmitter measures the pressure of
gases, vapours and liquids and is used in all areas of chemical and process engineering.
Ceramic sensor
The system pressure acts directly on the rugged ceramic diaphragm of the pressure
sensor deflecting it by a maximum of 0.025 mm (0.0098 in). A pressure-proportional
change in the capacitance is measured by the electrodes on the ceramic substrate and
diaphragm. The measuring range is determined by the thickness of the ceramic
diaphragm.
Metal sensor
The process pressure deflects the separating diaphragm with a filling liquid transmitting
the pressure to a resistance bridge. The bridge output voltage, which is proportional to
pressure, is then measured and processed.
Ceramic sensor
Diaphragm
Fig. 1.1: Sensor construction
The complete measuring system consists of
Barcon pressure transmitter with 4 mA ... 20 mA signal output with
superposed digital signal (HART communication) and
power supply 11.5 V ... 45 V DC, in Ex area 11.5 V ... 30 V DC.
Operation can be carried out via:
a digital display for operating and calling up measured values locally,
the universal handheld HART Communicator,
the Pepperl+Fuchs PACTware operating program.
Barcon
Process
Fig. 1.2: The measurement system
Ceramic substrate
Electrode
Metal sensor
Resistance
bridge
Filling fluid
4 mA ... 20 mA
Non-Ex area:
11.5 V ... 45 V DC
Ex-i area:
11.5 V ... 30 V DC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Barcon lhc

Table of Contents