• Old chimney flue with an inserted pipe of minimum Ø100/120 mm and with an external door which enables the chimney
cleaning.
• External chimney flue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum Ø100/120 mm: all
must be firmly attached to the wall. For chimney against wind effects please (see Fig. 5).
• Ducting system through T-unions which enables an easy cleaning without disassembling the pipes.
STUFE A PELLET
Fig. 8 - Example 2
LEGEND
Fig. 8
1
Insulating material
2
Inspection plug
3
Chimney inspection entrance
4
Minimum safety distance = 0,5 mt
5
Inclination ≥ 3°
6
Level section ≤ 1 mt
Fig. 9 - Example 3
LEGEND
Fig. 9
1
Insulating material
2
Inspection plug
3
Minimum safety distance = 0,5 mt
9