Summary of Contents for Symantec NetBackup 5200 Series
Page 1
Symantec NetBackup 5200 Series Troubleshooting Guide Release 2.0 NetBackup 5200 and 5220...
Page 2
Corporation or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners. This Symantec product may contain third party software for which Symantec is required to provide attribution to the third party ( Third Party Programs”). Some of the Third Party Programs are available under open source or free software licenses.
Page 3
Symantec Corporation 350 Ellis Street Mountain View, CA 94043 http://www.symantec.com Printed in the United States of America. 10 9 8 7 6 5 4 3 2 1...
The Technical Support group also creates content for our online Knowledge Base. The Technical Support group works collaboratively with the other functional areas within Symantec to answer your questions in a timely fashion. For example, the Technical Support group works with Product Engineering and Symantec Security Response to provide alerting services and virus definition updates.
Page 5
Troubleshooting that was performed before contacting Symantec Recent software configuration changes and network changes Licensing and registration If your Symantec product requires registration or a license key, access our technical support Web page at the following URL: www.symantec.com/business/support/ Customer service Customer service information is available at the following URL: www.symantec.com/business/support/...
Page 6
Support agreement resources If you want to contact Symantec regarding an existing support agreement, please contact the support agreement administration team for your region as follows: Asia-Pacific and Japan customercare_apac@symantec.com Europe, Middle-East, and Africa semea@symantec.com North America and Latin America...
NetBackup Appliance log file location information ....... 21 About troubleshooting decommissioning issues ......22 About troubleshooting FactoryReset problems ......23 Performing a factory reset on an appliance with a Symantec Storage Shelf attached ............25 About controlling the NetBackup and administration console processes ................
Page 8
Contents Resolving a problem that causes a factory reset to migrate data from a storage expansion unit ..........42 Resolving an expansion problem caused by pressing Ctrl C during expansion ............... 43 Resolving a boot order change problem ........45...
If you experience trouble with your appliance, it is important that you can define the problem and collect any supporting information. When you reach this point, you should contact Symantec Technical Support. A technical support representative works with you to diagnose the trouble and produce a satisfactory resolution.
Page 10
NetBackup Appliance log file location information” on page 21. You can also see more information on using error logs for NetBackup issues. See, Chapter 3, "Using logs" in the Symantec NetBackup Troubleshooting Guide. Step 2 Identify what you were doing...
Page 11
See the Symantec NetBackup Troubleshoting Guide. Step 6 Contact Technical Support The Symantec Technical Support Web site has a wealth of information that can help you solve NetBackup problems. Access Technical Support at the following URL: www.symantec.com/business/support/ NetBackup Appliance log file location information”...
Page 12
Logs Upload the log files to Symantec Technical Support. Set log levels. Export or remove CIFS and NFS shares. Refer to the Symantec NetBackup 5200 Series Command Reference Guide for more information on how to use the commands. Logs NetBackup 5200-log file locations...
To view NetBackup 52xx error information, download the following document from the Symantec Support Web site: http://www.symantec.com/docs/TECH136888 Note: At the time of the release of the NetBackup appliance, the error code information was not complete.
Page 14
For more details, consult the usage information of the script by using support -h. The following example describes how you can gather troubleshooting data for Symantec Technical Support to analyze. An application does not Wait for several minutes before you assume that the respond.
Page 15
Introduction About gathering information for NetBackup-Java applications Contact Symantec Technical Provide the log file and the output of the support script Support for analysis.
Page 16
Introduction About gathering information for NetBackup-Java applications...
Troubleshooting NetBackup problems” on page 17. Troubleshooting NetBackup Appliance problems” on page 18. Troubleshooting NetBackup problems The Symantec Technical Support site has a wealth of information that can help you solve NetBackup problems. See the following site for comprehensive troubleshooting details: http://www.symantec.com/business/support/...
Preliminary troubleshooting Configuration troubleshooting General test and troubleshooting Other troubleshooting procedures For complete information, see the Symantec NetBackup Troubleshooting Guide. Troubleshooting NetBackup Appliance problems” on page 18. Troubleshooting NetBackup Appliance problems These procedures for finding the cause of NetBackup errors are general in nature and do not try to cover every problem that can occur.
Troubleshooting procedures Troubleshooting NetBackup Appliance problems Steps for troubleshooting installation problems. (continued) Table 2-1 Step Action Description Step 3 Determine if you can Note: Before you install or use NetBackup on a Linux client, verify that the inetd install NetBackup (or xinetd) service is started on that computer.
NetBackup jobs may remain queued for long periods, even though all NetBackup processes and services are running. See, "Resolving full disk problems" in the Symantec NetBackup Troubleshooting Guide. If the backup or restore jobs are running slowly, verify that the network interface cards (NIC) are set to full duplex.
Logs Upload the log files to Symantec Technical Support. Set log levels. Export or remove CIFS and NFS shares. Refer to the Symantec NetBackup 5200 Series Command Reference Guide for more information on how to use the commands. Logs NetBackup 5200-log file locations...
To view NetBackup 52xx error information, download the following document from the Symantec Support Web site: http://www.symantec.com/docs/TECH136888 Note: At the time of the release of the NetBackup appliance, the error code information was not complete.
See the section, "Decommissioning a media server", in the Symantec NetBackup Administrator Guide , Volume I for more information on how to decommission a NetBackup media server. You can also refer to the following Technote on the Symantec Support Web site: http://www.symantec.com/docs/TECH31168 About troubleshooting FactoryReset problems The FactoryReset function is used to return an appliance to its default state.
Page 24
The following procedure describes how to perform a factory reset on an appliance with a Symantec Storage Shelf attached. Note: To avoid a factory reset failure, you must leave the Symantec Storage Shelf attached to the appliance when you perform this task.
The following procedure describes how to perform a factory reset on an appliance with a Symantec Storage Shelf attached. Note: To avoid a factory reset failure, you must leave the Symantec Storage Shelf attached to the appliance when you perform this task.
Page 26
Reset the appliance to the initial factory settings by entering the following command: Main_Menu > Support > FactoryReset Whenever you perform a factory reset on an appliance, it must be reconfigured. For complete details, see the Symantec NetBackup Appliance Getting Started Guide.
The NetBackup 5200 Administrator's Guide provides a complete list of the available commands. http://www.symantec.com/docs/DOC2792 About changing VxAT properties When troubleshooting your appliance, you may need to configure the Symantec Product Authentication Service (AT) Server parameters. The script is available for you to use to make changes to these changeVxATProperties parameters.
Troubleshooting procedures Troubleshooting NetBackup Appliance problems /opt/SYMCOpsCenterServer/bin/changeVxATProperties.sh About a login error message that does not go away You may encounter a login error message that states the following, "Please try after 5 minutes". If you receive this error message, and it does not disappear after five minutes, then you can use the following procedure to diagnose the issue.
Page 29
Behavior in regards to host name lookup and connectivity between NetBackup hosts and their role within the NetBackup domain Generates the reports that are meant for Symantec Technical Support. This utility provides the following types of information in its output: Running audit as Media Server.
Initiating tests... COMPLETED. Thank you for your patience. /log/dna/sample.name.symantec.com.NBDNA.20100907.191711.zip Archive created successfully! Return /log/dna/sample.name.symantec.com.NBDNA.20100907.191711.zip to Symantec Support upon request. NetBackup Support Utility ( nbsu You can use the utility to gather appropriate diagnostic information about nbsu NetBackup and the operating system. The NetBackup Troubleshooting Guide describes when you would use this utility, as well as how to run it.
Initiator 8 gb/s 0x21000024... *** Devices **** Device Vendor Host Type Remote Port /dev/sg0 SYMANTEC 10.182.0.209 FCPIPE (NBU 50x0) 0x21000024ff232438 /dev/sg2 SYMANTEC 10.182.0.209 FCPIPE (NBU 50x0) 0x21000024ff3162be *** Notes **** (NOTE: Ports in mode "Initiator*" are configured for target mode When SAN Client FT Media Server is active, however, are currently running in initiator mode, i.e.
Page 32
Troubleshooting procedures Troubleshooting NetBackup Appliance problems You can also use the command to verify and confirm the status Manage > FC Show of the SAN Client feature. From the output that you receive after you have run command, you can verify the following: Manage >...
Page 33
Troubleshooting procedures Troubleshooting NetBackup Appliance problems 04/25/11 22:25:22.857 [InitializeSDC24xx] ISP-2532 instance 2 PN 2 ssdid 0x815d (QLE2562) WWN:[21:00:00:24:ff:23:27:82] intlevel=58 PCI Express 04/25/11 22:25:22.857 [SetTargets] (Targets=2) 04/25/11 22:25:22.909 [InitSGRVPool] SGRVpool allocated with support for 322 * 256K buffers in two pools 04/25/11 22:25:22.909 [InitSGRVPool] WARN: SGRVpool space for 20 pipes of 16 buffers or 32 pipes of 10 buffers 04/25/11 22:25:23.949 [ActivateInterface24xx] PN=1 FWstate 4 Lost...
Page 34
Troubleshooting procedures Troubleshooting NetBackup Appliance problems Troubleshooting target mode port from the client Once the target ports are operational, you may need to continue your troubleshooting efforts from the client. You can use the NetBackup Administrator's console or use the command from the command-line interface.
Page 35
0 drwxr-xr-x 2 root root 0 Apr 25 11:06 . drwxr-xr-x 24 root root 0 Apr 24 17:55 .. Again, the expected entries are missing. At this time, Symantec recommends that you reload the FC HBA driver, with and then...
About troubleshooting storage expansion unit problems The following describes some problems that you may encounter with a storage expansion unit (Symantec Storage Shelf) and related expansion tasks. Links to topics that can help you resolve these problems are also included.
43. About NetBackup 5220 and Symantec Storage Shelf matched pairs When you order a NetBackup 5220 and a Symantec Storage Shelf together, these units are initialized together at the factory to create a matched pair. Matched pairs provide optimum performance and they should always be used together to...
Troubleshooting procedures About troubleshooting storage expansion unit problems To help you identify matched pairs, check the labels on the back of each Symantec Storage Shelf. Each unit has two labels that identify the serial numbers of the matched pair. Resolving an expansion hang problem If you attempt to expand the NetBackup disk storage pool to include the storage expansion unit and the process hangs, the process must be stopped.
Troubleshooting procedures About troubleshooting storage expansion unit problems vxprint appears in the disk group, do the following: disk_2 nbuapp Run the following command: vxdiskadm When the menu appears, select 3 to remove the disk. Identify the disk to be removed by entering disk_2. To confirm the disk to be removed, press y.
Troubleshooting procedures About troubleshooting storage expansion unit problems If the output shows that If the output shows that vxprint vxprint subdisks are part of but are subdisks are part of and also disk_2 disk_2 not part of any volumes, do the part of any volumes, do the following: following: Remove the subdisks from disk_2...
Page 42
Troubleshooting procedures About troubleshooting storage expansion unit problems To stop and then restart the NetBackup services so that backups are successful Stop the NetBackup services by entering the following command: Main > Support > Processes > NetBackup Stop Restart the NetBackup processes by entering the following command: Main >...
Page 43
Troubleshooting procedures About troubleshooting storage expansion unit problems Resolving an expansion problem caused by pressing Ctrl C during expansion If a user presses while expansion is in progress, the expansion fails. Ctrl C The following procedure describes how to clear the current condition and retry the expansion.
Page 44
Troubleshooting procedures About troubleshooting storage expansion unit problems If the output shows that If the output shows that vxtask list vxtask list a move operation is in progress, do a move operation is not in progress, the following: do the following: Stop the move operation by entering Verify that the pdvol or the advol disk the following command:...
Page 45
The following situations can cause the boot order to change, which can prevent the appliance from booting up. A new Symantec Storage Shelf is connected to an appliance that is currently in use. An appliance is restarted or turned on after the Symantec Storage Shelf is disconnected.
Page 46
Troubleshooting procedures About troubleshooting storage expansion unit problems On the setup screen, press the right arrow key until the Boot Options tab is highlighted, then press Enter. On the Boot Options screen, press the down arrow key until Hard Disk Order is highlighted, then press Enter.
Page 47
Troubleshooting procedures About troubleshooting storage expansion unit problems On the following screen, press the up or down arrow key until Boot Option #1 is highlighted, then press Enter. When the Boot Option #1 popup appears, select ICHx/ESB2 Embedded RAID and press Enter.
Page 48
Troubleshooting procedures About troubleshooting storage expansion unit problems Return to the Boot Options tab by pressing ESC. The correct boot order should now appear with the ICHx/ESB2 Embedded RAID set as Boot Option #1. Press F10 to save this configuration and exit from the setup. The appliance restarts automatically and should boot successfully.
Need help?
Do you have a question about the NetBackup 5200 Series and is the answer not in the manual?
Questions and answers