Setting Value (HS)+Dehumidification
Differential Value (DD), the equipment will
enter dehumidification state, the green led is
on, WORK2 output socket turns on. If the
green led is blinking, indicating that the
dehumidification device is in the state of the
dehumidification delay protection, WORK2
output socket turns off. If the measured
the green led is off, WORK2 output socket
turns off.
Example: HS=50.0%RH, HD=5.0%RH,
enter the dehumidification state, the green
led is on, WORK2 output socket turns on. If
WORK2 output socket turns off.
enter the humidification state, the red led is
on, WORK1 output socket turns on.
WORK1 output socket turns off.
Note: There is no need to judge the
differential value of humidification or
dehumidification when power on or exiting
the setting state. For example: when power
on or exiting the setting state HS=50.0%RH,
measured humidity) > 50.0%RH (HS), it will
50.0%RH (HS), the dehumidification stops,
then return to normal humidity control mode.
If PV < 50.0%RH, it will enter the humidifica-
14