Download Print this page

Mitsubishi Electric 800 Series Instruction Manual page 17

Hide thumbs Also See for 800 Series:

Advertisement

Setting
Pr.
Name
range
0 to 50Ω, 9999
Second motor constant
458
0 to 400mΩ,
(R1)
9999

0 to 50Ω, 9999
Second motor constant
459
0 to 400mΩ,
(R2)
9999

0 to 6000mH,
Second motor constant
9999

460
(L1) / d-axis inductance
0 to 400mH,
(Ld)
9999

0 to 6000mH,
Second motor constant
9999

461
(L2) / q-axis inductance
0 to 400mH,
(Lq)
9999

Second motor constant
0 to 100%,
462
(X)
9999
Second motor auto
463
0, 1, 11, 101
tuning setting/status
495
Remote output selection 0, 1, 10, 11
496
Remote output data 1
0 to 4095
497
Remote output data 2
0 to 4095
PLC function flash
0, 9696
498
memory clear
(0 to 9999)
Stop mode selection at
502
0 to 4
communication error
503
Maintenance timer 1
0(1 to 9998)
Maintenance timer 1
0 to 9998,
504
warning output set time
9999
505
Speed setting reference 1 to 590Hz
Emergency drive
0.1 to 600s,
514
dedicated retry waiting
9999
time
Emergency drive
515
1 to 200, 9999 1
dedicated retry count
0 to 590Hz,
522
Output stop frequency
9999
100, 111, 112,
121, 122, 123,
124, 200, 211,
212, 221, 222,
Emergency drive mode
223, 224, 300,
523
selection
311, 312, 321,
322, 323, 324,
400, 411, 412,
421, 422, 423,
424, 9999
0 to 590Hz/
Emergency drive
524
0 to 100%,
running speed
9999
MODBUS RTU
0 to 999.8s,
539
communication check
9999
time interval
USB communication
547
0 to 31
station number
USB communication check
548
0 to 999.8s, 9999 9999
time interval
549
Protocol selection
0 to 2
NET mode operation
550
command source
0, 1, 9999
selection
PU mode operation
551
command source
1 to 3, 9999
selection
552
Frequency jump range 0 to 30Hz, 9999 9999
0 to 100%,
553
PID deviation limit
9999
PID signal operation
554
0 to 7, 10 to 17 0
selection
555
Current average time
0.1 to 1.0s
556
Data output mask time 0 to 20s
Current average value
0 to 500A
557
monitor signal output
0 to 3600A
reference current
Second frequency search
0 to 32767,
560
gain
9999
PTC thermistor protection
0.5 to 30kΩ,
561
level
9999
Energization time
563
(0 to 65535)
carrying-over times
Operating time
564
(0 to 65535)
carrying-over times
Second motor
0 to 400Hz,
565
excitation current break
9999
point
Second motor
0 to 300%,
566
excitation current low-
9999
speed scaling factor
Second motor speed
0 to 200%,
569
control gain
9999
570
Multiple rating setting
0, 1
571
Holding time at a start
0 to 10s, 9999 9999
4 mA input check
573
1 to 4, 9999
selection
Second motor online
574
0, 1
auto tuning
Output interruption
0 to 3600s,
575
detection time
9999
Initial
Pr.
Name
value
Output interruption

576
detection level
9999
Output interruption
577
cancel level

Auxiliary motor
9999
578
operation selection
Motor connection
579
function selection
9999
MC switching interlock
580
time (multi-pump)
Start waiting time (multi-
581
pump)
9999
Auxiliary motor
582
connection-time
deceleration time
9999
Auxiliary motor
583
disconnection-time
acceleration time
0
Auxiliary motor 1
584
0
starting frequency
0
Auxiliary motor 2
585
starting frequency
0
Auxiliary motor 3
586
0
starting frequency
Auxiliary motor 1
587
0
stopping frequency
Auxiliary motor 2
0
588
stopping frequency
9999
Auxiliary motor 3
589
stopping frequency
60Hz
Auxiliary motor start
590
detection time
9999
Auxiliary motor stop
591
detection time
Traverse function
592
selection
9999
Maximum amplitude
593
amount
Amplitude
594
compensation amount
during deceleration
Amplitude
9999
595
compensation amount
during acceleration
Amplitude acceleration
596
time
Amplitude deceleration
597
time
9999
X10 terminal input
599
selection
9999
First free thermal
600
reduction frequency 1
First free thermal reduction
0
601
ratio 1
First free thermal
602
reduction frequency 2
1
First free thermal reduction
603
ratio 2
9999
First free thermal
604
reduction frequency 3
Power failure stop
9999
606
external signal input
selection
Motor permissible load
607
level
9999
Second motor
608
permissible load level
PID set point/deviation
609
input selection
1s
PID measured value
0s
610
input selection
Inverter

Acceleration time at a
rated
611
restart

current
Reverse rotation
9999
617
excitation current low-
speed scaling factor
9999
Speed smoothing
653
control
0
Speed smoothing cutoff
654
frequency
0
Analog remote output
655
selection
656
Analog remote output 1
9999
657
Analog remote output 2
658
Analog remote output 3
9999
659
Analog remote output 4
Increased magnetic
660
excitation deceleration
9999
operation selection
0
Magnetic excitation
661
increase rate
Increased magnetic
9999
662
excitation current level 0 to 300%
Control circuit
0
663
temperature signal
output level
1s
Setting
Initial
Pr.
range
value
Regeneration
0 to 590Hz
0Hz
665
avoidance frequency
gain
900 to 1100% 1000%
Power failure stop
668
frequency gain
0 to 3
0
User parameter auto
675
storage function
0 to 3
0
selection
Tuning data unit
684
0 to 100s
1s
switchover
686
Maintenance timer 2
0 to 100s
1s
Maintenance timer 2
687
warning output set time
0 to 3600s,
1s
688
Maintenance timer 3
9999
Maintenance timer 3
689
warning output set time
0 to 3600s,
1s
Second free thermal
9999
692
reduction frequency 1
0 to 590Hz
60Hz
Second free thermal
693
reduction ratio 1
Second free thermal
0 to 590Hz
60Hz
694
reduction frequency 2
Second free thermal
0 to 590Hz
60Hz
695
reduction ratio 2
0 to 590Hz
0Hz
Second free thermal
696
reduction frequency 3
0 to 590Hz
0Hz
699
Input terminal filter
Maximum motor
0 to 590Hz
0Hz
702
frequency
0 to 3600s
5s
Induced voltage
706
constant (phi f)
0 to 3600s
5s
707
Motor inertia (integer)
0 to 2
0
711
Motor Ld decay ratio
0 to 25%
10%
712
Motor Lq decay ratio
Starting resistance tuning
717
0 to 50%
10%
compensation
Starting magnetic pole
721
position detection pulse
0 to 50%
10%
width
724
Motor inertia (exponent)
0.1 to 3600s
5s
Motor protection current
725
level
0.1 to 3600s
5s
Auto Baudrate/Max
726
Master
0,1
0
727
Max Info Frames
Device instance
0 to 590Hz,
728
number (Upper 3 digits) 0 to 419
9999
9999
Device instance
729
number (Lower 4 digits) 0 to 9999
1 to 100%
100%
Second motor induced
0 to 590Hz,
738
9999
voltage constant (phi f)
9999
Second motor Ld decay
739
1 to 100%
100%
ratio
Second motor Lq decay
0 to 590Hz,
740
9999
ratio
9999
Second starting
741
resistance tuning
0, 1
1
compensation
Second motor magnetic
110 to 250%
150%
742
pole detection pulse width
110 to 250%,
9999
Second motor
9999
743
maximum frequency
1 to 5
2
Second motor inertia
744
(integer)
1 to 5, 101 to
3
Second motor inertia
105
745
(exponent)
0 to 3600s,
9999
Second motor
9999
746
protection current level
0 to 300%,
9999
9999
0 to 200%
0
Second PID action
753
selection
0 to 120Hz
20Hz
0, 1, 10, 11
0
Second PID control
1000%
754
automatic switchover
1000%
frequency
800 to 1200%
1000%
Second PID action set
755
point
1000%
Second PID
756
proportional band
0, 1
0
Second PID integral
757
time
0 to 40%, 9999 9999
Second PID differential
758
time
100%
759
PID unit selection
Pre-charge fault
760
0 to 100°C
0°C
selection
761
Pre-charge ending level
INVERTER FUNCTION SETTING
Parameter list
Setting
Initial
Name
range
value
0 to 200%
100%
0 to 200%
100%
1, 9999
9999
0, 1
0
0 (1 to 9998)
0
0 to 9998,
9999
9999
0 (1 to 9998)
0
0 to 9998,
9999
9999
0 to 590Hz,
9999
9999
1 to 100%
100%
0 to 590Hz,
9999
9999
1 to 100%
100%
0 to 590Hz,
9999
9999
5 to 50ms,
9999
9999
0 to 400Hz,
9999
9999
0 to 5000mV/
9999
(rad/s), 9999
10 to 999,
9999
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0 to 200%,
9999
9999
0 to 6000μs,
10000 to
9999
16000μs, 9999
0 to 7, 9999
9999
100 to 500%,
9999
9999
0 to 255
255
1 to 255
1
0
0
0 to 5000mV/
9999
(rad/s), 9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0 to 200%,
9999
9999
0 to 6000μs,
10000 to
9999
16000μs, 9999
0 to 400Hz,
9999
9999
10 to 999,
9999
9999
0 to 7, 9999
9999
100 to 500%,
9999
9999
0, 10, 11, 20,
21, 50, 51, 60,
61, 70, 71, 80,
81, 90, 91,
100, 101,
0
1000, 1001,
1010, 1011,
2000, 2001,
2010, 2011
0 to 590Hz,
9999
9999
0 to 100%,
9999
9999
0.1 to 1000%,
100%
9999
0.1 to 3600s,
1s
9999
0.01 to 10.00s,
9999
9999
0 to 43, 9999
9999
0, 1
0
0 to 100%,
9999
9999
17

Advertisement

loading