5.2
Parameter list
For simple variable-speed operation of the inverter, the initial values of the parameters may be used as they are. Set the necessary parameters to meet the load
and operational specifications. Parameter setting, change and check can be performed from the operation panel.
Setting
Pr.
Name
range
0
Torque boost
0 to 30%

1
Maximum frequency
0 to 120Hz

2
Minimum frequency
0 to 120Hz

3
Base frequency
0 to 590Hz

Multi-speed setting
4
0 to 590Hz

(high speed)
Multi-speed setting
5
0 to 590Hz

(middle speed)
Multi-speed setting (low
6
0 to 590Hz

speed)
7
Acceleration time
0 to 3600s

8
Deceleration time
0 to 3600s

0 to 500A
Electronic thermal O/L
9

relay
0 to 3600A
DC injection brake
0 to 120Hz,
10
operation frequency
9999
DC injection brake
11
0 to 10s, 8888 0.5s
operation time
DC injection brake
12
0 to 30%
operation voltage
13
Starting frequency
0 to 60Hz
14
Load pattern selection
0, 1, 12 to 15
15
Jog frequency
0 to 590Hz

Jog acceleration/
16
0 to 3600s

deceleration time
17
MRS input selection
0, 2, 4
High speed maximum
18
0 to 590Hz
frequency
0 to 1000V,
19
Base frequency voltage
8888, 9999
Acceleration/
20
deceleration reference
1 to 590Hz
frequency
Acceleration/
21
deceleration time
0, 1
increments
Stall prevention
22
operation level
0 to 400%
(Torque limit level)
Stall prevention
operation level
23
0 to 200%, 9999 9999
compensation factor at
double speed
24 to
Multi-speed setting (4
0 to 590Hz,
27
speed to 7 speed)
9999
Multi-speed input
28
0, 1
compensation selection
Acceleration/
29
deceleration pattern
0 to 3, 6
selection
0 to 2, 10, 11,
20, 21,
Regenerative function
30
100 to 102,
selection
110, 111, 120,
121
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
0 to 590Hz,
9999
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
0, 1 to 9998
Up-to-frequency
41
0 to 100%
sensitivity
Output frequency
42
0 to 590Hz
detection
Output frequency
0 to 590Hz,
43
detection for reverse
9999
rotation
Second acceleration/
44
0 to 3600s
deceleration time
Second deceleration
0 to 3600s,
45
time
9999
46
Second torque boost
0 to 30%, 9999 9999
Second V/F (base
0 to 590Hz,
47
frequency)
9999
Second stall prevention
48
0 to 400%
operation level
Second stall prevention
0 to 590Hz,
49
operation frequency
9999
Second output
50
0 to 590Hz
frequency detection
0 to 500A,
9999

Second electronic
51
thermal O/L relay
0 to 3600A,
9999

Pr.
Name
Initial
value
1%
120Hz

Operation panel main
52
60Hz

monitor selection
0Hz
60Hz
60Hz
CA terminal function
30Hz
54
selection
10Hz
15s
Frequency monitoring
55
30s
reference
Inverter

Current monitoring
rated
56
reference

current
3Hz
57
Restart coasting time
58
Restart cushion time
Remote function
59
selection
1%
Energy saving control
60
0.5Hz
selection
1
65
Retry selection
5Hz
Stall prevention
66
operation reduction
0.5s
starting frequency
Number of retries at
0
67
fault occurrence
120Hz

68
Retry waiting time
60Hz

69
Retry count display erase
9999
70
Parameter for manufacturer setting. Do not set.
60Hz
71
Applied motor
0
PWM frequency
72
selection
110%
73
Analog input selection
74
Input filter time constant 0 to 8
Reset selection/
9999
disconnected PU
75
detection/PU stop
0
selection
0
Fault code output
76
selection
0
Parameter write
77
selection
9999
Reverse rotation
78
prevention selection
9999
Operation mode
9999
79

selection
9999
9999
80
Motor capacity
9999
0
81
Number of motor poles
10%
6Hz
82
Motor excitation current
9999
83
Rated motor voltage
5s
84
Rated motor frequency
Excitation current break
9999
85
point
Excitation current low-
86
speed scaling factor
9999
Speed control gain
89
(Advanced magnetic
110%
flux vector)
0Hz
90
Motor constant (R1)
30Hz
91
Motor constant (R2)
9999
Setting
Initial
Pr.
range
value
0, 5 to 14, 17,
18, 20, 23 to
Motor constant (L1)/d-
92
25, 34, 38, 40
axis inductance (Ld)
to 45, 50 to 57,
0
61, 62, 64,
67 to 69,
81 to 96, 98,
Motor constant (L2)/q-
93
100
axis inductance (Lq)
1 to 3, 5 to 14,
17, 18, 21, 24,
94
Motor constant (X)
34, 50, 52, 53,
61, 62, 67, 69,
1
Online auto tuning
70, 85,
95
selection
87 to 90, 92,
93, 95, 98
Auto tuning setting/
96
status
0 to 590Hz
60Hz
100
V/F1 (first frequency)
Inverter
0 to 500A

rated
V/F1 (first frequency
101
0 to 3600A

current
voltage)
0, 0.1 to 30s,
V/F2 (second
9999
102
9999
frequency)
0 to 60s
1s
V/F2 (second frequency
103
voltage)
0 to 3, 11 to 13 0
104
V/F3 (third frequency)
0, 4, 9
0
V/F3 (third frequency
105
voltage)
0 to 5
0
106
V/F4 (fourth frequency)
0 to 590Hz
60Hz
V/F4 (fourth frequency
107
voltage)
0 to 10, 101 to
0
110
108
V/F5 (fifth frequency)
0.1 to 600s
1s
V/F5 (fifth frequency
0
0
109
voltage)
Check valve deceleration
111
0 to 6, 13 to
time
16, 8090,
PU communication
8093, 8094,
0
117
station number
9090, 9093,
9094
PU communication
118
speed
0 to 15

2
PU communication stop
0 to 6, 25

119
bit length / data length
0 to 7, 10 to 17 1
PU communication parity
120
1
check
0 to 3, 14 to
Number of PU
121
17, 1000 to
communication retries
1003, 1014 to
PU communication
1017

122
check time interval
0 to 3, 14 to
PU communication
17, 100 to 103,
123
14
waiting time setting
114 to 117,
PU communication CR/
1000 to 1003,
124
LF selection
1014 to 1017,
Terminal 2 frequency
1100 to 1103,
125

setting gain frequency
1114 to 1117

Terminal 4 frequency
126

0 to 2
0
setting gain frequency
PID control automatic
127
0 to 2
0
switchover frequency
0 to 2
0
0 to 4, 6, 7
0
128
PID action selection
0.4 to 55kW,
9999

9999
0 to 3600kW,
9999

129
PID proportional band
2, 4, 6, 8, 10,
9999
12, 9999
130
PID integral time
0 to 500A,
9999

9999
131
PID upper limit
0 to 3600A,
9999

132
PID lower limit
0 to 1000V
575V
10 to 400Hz,
9999
133
PID action set point
9999
0 to 400Hz,
9999
134
PID differential time
9999
0 to 300%,
Electronic bypass
9999
135
9999
sequence selection
MC switchover interlock
0 to 200%,
136
9999
time
9999
137
Start waiting time
0 to 50Ω,
Bypass selection at a
9999

138
9999
fault
0 to 400mΩ,
Automatic switchover
9999

139
frequency from inverter
0 to 50Ω,
to bypass operation
9999

9999
Backlash acceleration
140
0 to 400mΩ,
stopping frequency
9999

INVERTER FUNCTION SETTING
Parameter list
Setting
Initial
Name
range
value
0 to 6000mH,
9999

9999
0 to 400mH,
9999

0 to 6000mH,
9999

9999
0 to 400mH,
9999

0 to 100%,
9999
9999
0, 1
0
0, 1, 11, 101
0
0 to 590Hz,
9999
9999
0 to 1000V
0V
0 to 590Hz,
9999
9999
0 to 1000V
0V
0 to 590Hz,
9999
9999
0 to 1000V
0V
0 to 590Hz,
9999
9999
0 to 1000V
0V
0 to 590Hz,
9999
9999
0 to 1000V
0V
0 to 3600s,
9999
9999
0 to 31
0
48, 96, 192, 384,
192
576, 768, 1152
0, 1, 10, 11
1
0 to 2
2
0 to 10, 9999
1
0, 0.1 to
9999
999.8s, 9999
0 to 150ms,
9999
9999
0 to 2
1
0 to 590Hz
60Hz
0 to 590Hz
60Hz
0 to 590Hz,
9999
9999
0, 10, 11, 20,
21, 50, 51, 60,
61, 70, 71, 80,
81, 90, 91,
100, 101,
0
1000, 1001,
1010, 1011,
2000, 2001,
2010, 2011
0.1 to 1000%,
100%
9999
0.1 to 3600s,
1s
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0.01 to 10s,
9999
9999
0, 1
0
0 to 100s
1s
0 to 100s
0.5s
0, 1
0
0 to 60Hz,
9999
9999
0 to 590Hz
1Hz
15

Advertisement

loading