Download Print this page

Specifications - Mitsubishi Electric 800 Series Instruction Manual

Hide thumbs Also See for 800 Series:

Advertisement

Rating
7

SPECIFICATIONS

7.1
Rating
Model FR-F860-[ ]
Inverter capacity (kW)
SLD
Applicable motor
capacity (kW)

LD
SLD
Rated capacity
(kVA)

LD
SLD
Rated current (A)

LD
SLD
Overload current
rating

LD
Rated voltage

Rated input
AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Without DC
reactor
Rated input
current (A)

With DC
reactor

Without DC
reactor
Power supply
capacity (kVA)

With DC
reactor
Protective structure (IEC 60529)
Cooling system
Approx. mass (kg)

The applicable motor capacity indicated is the maximum capacity applicable for use of the 4-pole standard motor.

The rated output capacity indicated assumes that the output voltage is 575 V.

When an operation is performed with the carrier frequency set to 3 kHz or more, and the inverter output current reaches the value indicated in the parenthesis, the
carries frequency is automatically lowered. The motor noise becomes louder accordingly.

The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for the inverter
and motor to return to or below the temperatures under 100% load.

The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However, the maximum
point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about

The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor and cables) affects the
rated input current.

The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of the input reactor and
cables).
22
SPECIFICATIONS
00680
01080
45.0
75.0
45.0
75.0
45.0
75.0
68.0
108.0
62.0
99.0
68.0 (57.8)
108.0 (91.8)
62.0 (52.7)
99.0 (84.1)
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40°C
120% 60 s, 150% 3 s (inverse-
time characteristics) at
surrounding air temperature of
40°C
Three-phase 525 to 600 V
Three-phase 525 to 600 V 60 Hz
472 to 660 V 60 Hz
±5%
SLD
87.0
LD
79.0
SLD
68.0 (57.8)
108.0 (91.8)
LD
62.0 (52.7)
99.0 (84.1)
SLD
86.8
LD
79.1
SLD
68.0
108.0
LD
62.0
99.0
Open type (IP00)
Forced air
36.0
41.0
01440
01670
02430
90.0
110.0
132.0
110.0
110.0
185.0
90.0
110.0
150.0
144.0
167.0
242.0
131.0
152.0
221.0
144.0 (122.0)
167.0 (141.0)
243.0 (206.0)
131.0 (122.0)
152.0 (129.0)
221.0 (187.0)
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
144.0 (122.0)
167.0 (141.0)
243.0 (206.0)
131.0 (122.0)
152.0 (129.0)
221.0 (187.0)
144.0
167.0
242.0
131.0
152.0
221.0
52.0
52.0
55.0
02890
03360
160.0
220.0
220.0
260.0
185.0
220.0
288.0
335.0
254.0
303.0
289.0 (245.0)
336.0 (285.0)
255.0 (216.0)
304.0 (258.0)
289.0 (245.0)
336.0 (285.0)
255.0 (216.0)
304.0 (258.0)
288.0
335.0
254.0
303.0
112.0
115.0
.
04420
250.0
335.0
300.0
441.0
401.0
442.0 (375.0)
402.0 (341.0)
442.0 (375.0)
402.0 (341.0)
441.0
401.0
153.0