Quick Links

Nordson Corporation
OPERATOR'S CARD
P/N 107 104A
r
Pro-Flo
Controller
Safety Symbols
The following symbols warn against dangers or possible
sources of danger. Become familiar with them! Failure
to heed a warning symbol could lead to personal injury
and/or damage to the unit or other equipment.
Heed all warning symbols that appear in this document,
the operator's manual, or on the equipment.
WARNING: Failure to observe this warning may
result in personal injury, death, or equipment
damage.
WARNING: Risk of electrical shock. Failure to
observe this warning may result in personal injury
or death or equipment damage.
System Components
See Figure 1. The Pro-Flo Controller automates the
control of Pro-Flo guns. Use the operator interface (3) to
select and define production parameters. The diagnostic
panel (5) displays the system status. Use the LAMP
TEST key (4) to test the lights on the panel. When a
fault is detected, the alarm tower (1) lights and the type
of fault is indicated on the diagnostic panel. The robot
signal indicators (2) on the diagnostic panel light when
signals are received from the robot controller. Under
normal operating conditions, these lights flash on and off
in a specific sequence.
107 104A
Issued 6/95
1. Alarm tower
2. Robot signal indicators
3. Operator interface
4. LAMP TEST key
5. Diagnostic panel
Please Note
This operator's card contains only information necessary
for daily operation and troubleshooting. For other
information, refer to the product manual.
WARNING: Allow only qualified personnel to
perform the following tasks. Observe and follow
the safety instructions in this document and all
other related documentation.
Always follow the instructions given in the operator's
card and operating manual.
5
4
Fig. 1
Pro-Flo Controller
1
1
2
3
2511001A
Manual 25-11

Advertisement

loading

Summary of Contents for Nordson Pro-Flo

  • Page 1 System Components See Figure 1. The Pro-Flo Controller automates the control of Pro-Flo guns. Use the operator interface (3) to select and define production parameters. The diagnostic panel (5) displays the system status. Use the LAMP TEST key (4) to test the lights on the panel.
  • Page 2: Fault Correction

    Controls See Figure 2. The keys and indicators on the operator Fault Correction interface panel are described below: When a Pro-Flo system fault is detected, the alarm tower lights and the diagnostic panel indicates where faults Fig. Item Function occurred. Select the HELP screen to display a ref.
  • Page 3: Daily Operation

    Set Up Set the parameters for Pro-Flo dispensing from the Set Gun On and Gun Off to delay the digital controller’s SET-UP screen. Highlight and select SET-UP, then reaction to the gun-on and gun-off signals from the robot highlight and select any of the following prompts: controller.
  • Page 4: Back Up Mode

    Material supply pressure low Increase the material supply pressure. Refer to Drum dispense material. uploader manual. Nozzle blocked Remove and clean the nozzle. Refer to Pro-Flo gun manual. Material supply hose blocked Check material supply hose. Unblock it. Refer to Pro-Flo gun manual.
  • Page 5 You must adjust the timing sequence of output signals Set the robot timing as illustrated in Figure 3 for from the robot controller to suit the Pro-Flo controller. start up (1) This is normally done during installation, but may need shut down (2) readjusting occasionally.
  • Page 6 Fig. 3 Timing of robot signals 1. Start up 2. Shut down 3. Emergency stop 1995 Nordson Corporation Original copyright date 1995. Nordson, the Nordson logo and Pro-Flo are registered trademarks of Nordson Corporation. Manual 25-11 107 104A Issued 6/95...