This is a Nordson Corporation publication which is protected by copyright. Original copyright date 2001. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. Trademarks...
Intended Use Use of Nordson equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property.
To prevent injury, be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot surfaces, sharp edges, energized electrical circuits, and moving parts that cannot be enclosed or otherwise guarded for practical reasons. E 2001 Nordson Corporation Manual 25-23 1006453A All rights reserved...
The treatment that doctors recommend for an injection injury to the hand includes immediate decompression of the closed vascular compartments of the hand to release the underlying tissue distended by the injected paint, judicious wound debridement, and immediate antibiotic treatment. E 2001 Nordson Corporation 1006453A Manual 25-23 All rights reserved...
Clean, maintain, test, and repair equipment according to the instructions in your equipment documentation. Use only replacement parts that are designed for use with original equipment. Contact your Nordson representative for parts information and advice. E 2001 Nordson Corporation Manual 25-23...
“Iodo-” Check your material MSDS or contact your material supplier for more information. If you must use halogenated hydrocarbon solvents, contact your Nordson representative for information about compatible Nordson components. Action in the Event of a If a system or any equipment in a system malfunctions, shut off the...
Internal replaceable parts, such as fuses and the power supply, are accessible by opening the enclosure door handle (5). Power to the controller is shut off by opening the knife disconnect (4). E 2001 Nordson Corporation Manual 25-23 1006453A All rights reserved...
Page 11
Fig. 1 Ejector Gun Controller Components and Dimensions 1. Main power connector (from robot) 4. Knife disconnect 6. Gun communication connector 2. Light 5. Door handle 7. Keypad 3. Ground fault lights E 2001 Nordson Corporation 1006453A Manual 25-23 All rights reserved Issued 6/01...
3. Make all system electrical connections according to the system schematics provided in your system documentation. If you have any questions, contact your Nordson representative. WARNING: Allow only qualified personnel to perform the 4. Operation following tasks.
Page 13
Accesses special features and configuration of operating parameters [MENU] Returns to the main menu of an application [F1] – [F2] Displays any application screen assigned to the key E 2001 Nordson Corporation 1006453A Manual 25-23 All rights reserved Issued 6/01...
Refer to Table 3 for information to help you navigate in the MANUAL screen. Table 3 MANUAL Screen Functions Press Access the MANUAL DISPENSE screen Access the MANUAL REFILL screen [F1] Start [F2] Stop E 2001 Nordson Corporation 1006453A Manual 25-23 All rights reserved Issued 6/01...
Ejector gun refill and dispense. NOTE: To perform functions in the SETUP menu, you must enter an access code. Contact your Nordson Corporation representative if you do not have the proper access code. Table 4 SETUP Menu Navigation...
This section contains troubleshooting procedures. These procedures cover only the most common problems that you may encounter. If you cannot solve the problem with the information given here, contact your local Nordson representative for help. E 2001 Nordson Corporation 1006453A...
Load blocked new material or troubleshoot for material blockages, as indicated. Refer to your unloader manual for more information. E 2001 Nordson Corporation Manual 25-23 1006453A All rights reserved Issued 6/01...
Refer to Adjusting the Speed Control Valves in the Installation section of the Ejector Gun manual to modify the speed control valve adjustments. E 2001 Nordson Corporation 1006453A Manual 25-23 All rights reserved Issued 6/01...
4. Close the fuse holder(s). 5. Correct the problem that caused the fuse to blow. 6. Close the controller door and restore the power connection at the knife disconnect. E 2001 Nordson Corporation Manual 25-23 1006453A All rights reserved Issued 6/01...
4. Install the new power supply onto the DIN rail. 5. Connect the wires per the electrical schematics provided with your system documentation. 6. Close the controller door and restore the power connection at the knife disconnect. E 2001 Nordson Corporation 1006453A Manual 25-23 All rights reserved Issued 6/01...
7. Put the PLC in the software RUN mode. 8. Plug in the communication cable. 9. Close the controller door and restore the power connection at the knife disconnect. E 2001 Nordson Corporation Manual 25-23 1006453A All rights reserved Issued 6/01...
Ejector Gun Controller To order parts, call the Nordson Customer Service Center or your local 8. Parts Nordson representative. Use the parts list, and the accompanying illustration, to describe and locate parts correctly. Using the Illustrated Parts Numbers in the Item column correspond to numbers that identify parts in illustrations following each parts list.
Page 24
S Power supply, 2.1 amp @ 24 Vdc 1005874 S Fuse, 939094 S Fuse, 2 amp 1002383 S Cable, communication 235935 S Programmable logic controller 341358 2523004A Fig. 4 Ejector Gun Controller Replacement Parts E 2001 Nordson Corporation Manual 25-23 1006453A All rights reserved Issued 6/01...