ELECTRICAL EQUIPMENT

1- Gearmotor; 220-230V power supply, 3x1.5mm² cable (comply with the current standards)
2- Photocell transmitter 2x0.5mm² cable
3- Photocell receiver 4x0.5 mm² cable
4- Antenna screened coaxial cable.
5- Frame 4x0.5mm² cable
6- Rack
7- Key selector 3x0.5mm² cable
8- 24 VDC flashing light signaller 2x0.75mm² cable (if 12x0.75 mm² RX cable is present)
9- Omnipolar magnetothermal switch with minimum contact opening of 3 mm Power supply line to the control unit
220-230V, 50-60Hz, 3x1.5 mm² cable (comply with the current standards).
ELECTRICAL EQUIPMENT
Operator
Type
Supply voltage
Motor power supply
Power absorbed
Current absorbed
Thermal cutout
Pick-up capacitor
Max speed
Maximum torque
Operating temperature
Degree of protection
Operating frequency (%)
Maximum leaf length
Limit switch

PRELIMINARY WARNINGS

Check that the gate structure is in conformity with the regulations in force and that leaf movement is linear without
friction.
SL 244
Irreversible electromechanical gearmotor
220/230Vac 50-60Hz
24Vdc
MAX 100W
MAX 5A
-
-
0,15 m/sec
9 N/m
-20°C + 60°C
IP 55
50% (at 20°C)
5 m
4
SL 344
24Vdc
MAX 100W
MAX 5A
-
-
0,2 m/sec
12 N/m
-20°C + 60°C
IP 55
90% (at 20°C)
10 m
4