4.13 PACE-Bus RS485

A6V11940317_en--_a
Both PC1001-A2 and PC1002-A2 Novigo Core audio matrix boards provide 4
'PACE-Bus' (RS485) connectors ('1-RS485' to '4-RS485') in the options area.
These connectors can be used to connect the 'PACE-Bus' (RS485) operating
terminals and the 'PACE-Bus' (RS485) call stations.

Fig. 20: 'PACE-Bus' (RS485) connection

'PACE-Bus' (RS485) connectors - '1-RS485' to '4-RS485'
Pin
Description
1
D-
2
D+
3
GND
4
24 V

Table 14: 'PACE-Bus' (RS485) connectors - '1-RS485' to '4-RS485'

These connectors are only used to connect the internal 'PACE-Bus' (RS485)
components in the cabinet.
If these connectors are used to connect the external 'PACE-Bus' (RS485)
components, they must be secured with the components below:
The RS485 isolator: 'ICPDAS I-7510 (RS485, isolated)' PNA2009-A1
The 'MeanWell SD-50B-24 DC/DC' PCA2011-A1 or the 'MeanWell SD-100B-24
DC/DC' PCA2018-A1
The 'Ground fault monitoring (24V)' PCA2001-A1
It ensures that a short circuit on the external wiring does not influence the internal
function of the cabinet.
Mounting/Installation
PACE-Bus RS485
Remark
RS485 data -
RS485 data +
-
-
4