Westermo Lynx DSS L208-F2G-S2-EX User Manual

Westermo Lynx DSS L208-F2G-S2-EX User Manual

Industrial ethernet 8-port device server switch

Advertisement

Quick Links

www.wester mo.com
Lynx DSS L208-F2G-S2-EX
Industrial Ethernet 8-port Device Server Switch

Advertisement

Table of Contents
loading

Summary of Contents for Westermo Lynx DSS L208-F2G-S2-EX

  • Page 1 Lynx DSS L208-F2G-S2-EX Industrial Ethernet 8-port Device Server Switch...
  • Page 2 6643-22701...
  • Page 3: General Information

    Under no circumstances shall Westermo be responsible for any loss of data or income or any special, incidental, and consequential or indirect damages howsoever caused.
  • Page 4: Safety And Regulations

    Safety and Regulations Warning signs are provided to prevent personal injuries and/or damages to the product. The following levels are used: Level of warning Description Consequence Consequence personal injury material damage Indicates a potentially Possible death or Major damage to the hazardous situation major injury product...
  • Page 5 WARNING - PROTECTIVE FUSE It must be possible to disconnect manually from the power supply. Ensure compliance to national installation regulations. Replacing the internal fuse must only be performed by Westermo qualified personell. WARNING - POWER SUPPLY CONNECTION There are safety regulations on which power sources that shall be used in conjunction with the product.
  • Page 6 WARNING - REDUCE THE RISK OF FIRE To reduce the risk of fire, use only telecommunication line cords with a cable diameter of AWG 26 or larger. Regarding power cable dimensions, see Interface Specifications. CAUTION - CLASS 1 LASER PRODUCT Do not look directly into a fibre optical port or any connected fibre, although the product is designed to meet the Class 1 Laser regulations and complies with 21 CFR 1040.10 and 1040.11.
  • Page 7 If the product is used in a manner not according to specification, the protection provided by the equipment may be impaired. If the product is not working properly, contact the place of purchase, nearest Westermo distributor office or Westermo technical support.
  • Page 8: Atex Certification

    ATEX certification ATEX certification number Baseefa12ATEX0119X Standards EN 60079-0, EN 60079-15 Certification code Ex nA IIC T3 Gc (-40°C ≤ Ta ≤ +70°C) ATEX code II 3G Specific Conditions of Use The equipment must be installed in an area of not more than pollution degree 2 in accordance with IEC/EN 60664-1, and in an enclosure that provides a minimum degree of protection of at least IP54 and complies with the relevant requirements of EN 60079-0 and EN 60079-15.
  • Page 9 SFP option approved transceivers SFP Transceivers, 100 Mbit 1100-0131 MLC2, Multimode, LC-Connector, 2 km, 1310 nm 1100-0132 SLC20, Singlemode, LC-Connector, 20 km, 1310 nm 1100-0133 SLC40, Singlemode, LC-Connector, 40 km, 1310 nm 1100-0134 SLC80, Singlemode, LC-Connector, 80 km, 1550 nm 1100-0140 SLC120, Singlemode, LC-Connector, 120 km, 1550 nm BiDi Transceivers, 100 Mbit 1100-0145 SLC15-BiDi-A, Singlemode, BiDi, 20 km, 1310 nm TX, 1550 nm RX...
  • Page 10 ATEX-Zertifizierung ATEX-Zulassungsnummer Baseefa12ATEX0119X Standards EN 60079-0, EN 60079-15 Zertifizierungscode Ex nA IIC T3 Gc (-40 °C ≤ Ta ≤ +70 °C) ATEX-Code II 3G Spezifische Einsatzbedingungen Die Geräte müssen in einem Bereich welcher einem maximalen Verschmutzungsgrad der Stufe 2 gemäß IEC/EN 60664-1 entspricht und in einem Gehäuse, das einen Schutzgrad von mindestens IP54 bietet und die relevanten Anforderungen von N 60079-0 und EN 60079-15 erfüllt, installiert werden.
  • Page 11 Für SFP-Option zugelassene Transceiver SFP-Transceiver, 100 Mbit 1100-0131 MLC2, Multimode, LC-Anschluss, 2 km, 1310 nm 1100-0132 SLC20, Singlemode, LC-Anschluss, 20 km, 1310 nm 1100-0133 SLC40, Singlemode, LC-Anschluss, 40 km, 1310 nm 1100-0134 SLC80, Singlemode, LC-Anschluss, 80 km, 1550 nm 1100-0140 SLC120, Singlemode, LC-Anschluss, 120 km, 1550 nm BiDi-Transceiver, 100 Mbit 1100-0145 SLC15-BiDi-A, Singlemode, BiDi, 20 km, 1310 nm TX, 1550 nm RX 1100-0146 SLC15-BiDi-B, Singlemode, BiDi, 20 km, 1550 nm TX, 1310 nm RX...
  • Page 12 Certification ATEX Numéro de certification ATEX Baseefa12ATEX0119X Normes EN 60079-0, EN 60079-15 Code de certification Ex nA IIC T3 Gc (-40°C ≤ Ta ≤ +70°C) Code ATEX II 3G Conditions spéciales d'utilisation L'équipement doit être installé dans une zone où le degré de pollution ne dépasse pas le degré...
  • Page 13 Transmetteurs optionnels SFP certifiés Transmetteurs SFP, 100 Mbit 1100-0131 MLC2, multimode, connecteur LC, 2 km, 1310 nm 1100-0132 SLC20, monomode, connecteur LC, 20 km, 1310 nm 1100-0133 SLC40, monomode, connecteur LC, 40 km, 1310 nm 1100-0134 SLC80, monomode, connecteur LC, 80 km, 1550 nm 1100-0140 SLC120, monomode, connecteur LC, 120 km, 1550 nm Transmetteurs Bi-Di, 100 Mbit 1100-0145 SLC15 Bi-Di A, monomode, Bi-Di, 20 km, 1310 nm TX, 1550 nm, RX...
  • Page 14: Agency Approvals And Standards Compliance

    Agency approvals and standards compliance Type Approval / Compliance EN 61000-6-1, Immproducty residential environments EN 61000-6-2, Immproducty industrial environments EN 61000-6-3, Emission residential environments EN 61000-6-4, Emission industrial environments EN 50121-4, Railway signalling and telecommunications apparatus IEC 62236-4, Railway signalling and telecommunications apparatus Safety UL 62368-1, Safety Communication Technology Marine...
  • Page 15: Declaration Of Conformity

    Declaration of Conformity Hereby, Westermo declares that this product is in compliance with applicable EU directives. The full EU declaration of conformity and other detailed information is available at www.westermo.com/support/product-support.
  • Page 16: Hardware Overview

    Hardware Overview Location of interface ports and LEDs LED Indicators Power connection Position Direction* / description Output values Out / VBUS In/out / D- = 5 VDC max In/out / D+ = 400 mA max Shield SFP transceivers RS-232, RS-422/485 Ethernet connection TX (4 ports) Position Signale Direction Description Input/output values...
  • Page 17 RS-422/485 (for more details see below) Signal Position Direction Description Input/Output values RS-422 RS-485 (4-wire) (2-wire) No. 1 T+/R+ Out/In RS-422: Transmit RS-485: Transmit/Receive No. 2 Out/In RS-422: Transmit T-/R- RS-485: Transmit/Receive U = 5 V max No. 3 RS-422: Receive I = 250 mA max No.
  • Page 18: Interface Specifications

    Interface specifications Power Operating voltage Rated: 24 to 48 VDC Operating: 19 to 60 VDC Rated current 250 mA (380 mA) @ 24 VDC (with 500 mA USB load) 120 mA (188 mA) @ 48 VDC (with 500 mA USB load) Rated frequency Inrush current, I 22.7·mA²s @ 48 VDC...
  • Page 19 RS-232/422/485 Electrical specification Configurable for EIA RS-232 or EIA RS-422/485 Data rate RS-232 50 bit/s - 115.2 kbit/s RS-422/485 50 bit/s - 2 Mbit/s Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits (2 stop bits only when no parity is set) Circuit type TNV-1...
  • Page 20 LVTTL-level (service port, shall not be connected during nor- mal operation. Only to be used during maintenance.) Data rate 115.2 kbit/s Data format 8 data bits, no parity, 1 stop bit, no flow control Circuit type SELV Connection 2.5 mm jack, use only Westermo cable 1211-2027 6643-22701...
  • Page 21: Sfp Transceivers

    SFP Transceivers The product supports UL and IEC certified transceivers only. See Westermo's modular transceivers datasheets 100 Mbit and 1 Gbit for supported SFP transceivers, which can be downloaded from the product support pages at www.westermo.com/support/ productsupport. Each SFP slot can hold one SFP transceiver. See "Transceiver User Guide 6100-0000"...
  • Page 22: Type Tests And Environmental Conditions

    Type tests and environmental conditions Environmental phenomena Basic standard Description Test levels EN 61000-4-2 Enclosure Contact: ±6 kV Air: ±8 kV Fast transients EN 61000-4-4 Power port ±2 kV Ethernet ±2 kV Status out/Digital in ±2 kV Serial ports ±2 kV Enclosure ±2 kV Surge...
  • Page 23 Environmental Temperatures EN 60068-2-1 Operating -40 to +70°C (-40 to +158°F)* EN 60068-2-2 Storage and transport -50 to +85°C (-58 to +185°F) Humidity EN 60068-2-30 Operating 5 to 95 % relative humidity Storage and transport Altitude Operating 2 000 m / 70 kPa Service life Operating 10 year...
  • Page 24: Connection To Console Port

    The following steps needs to be taken 1. Connect the serial diagnostic cable to the console port (use only Westermo cable 1211-2027). 2. Connect cable to your computer (USB port, if drivers are needed they can be downloaded from our Web page).
  • Page 25: Connector Information

    Connector Information Power connection Product 4-position Direction Description Input values marking No. 1 +DC1 Input Supply voltage input DC1 = (19 - 60) VDC No. 2 +DC2 Input Supply voltage input DC2 = 380 mA @ 24 VDC No. 3 -COM Input Common...
  • Page 26: Led Indicators

    LED indicators Status Description Product has no power. GREEN All OK, no alarm condition. Alarm condition, or until product has started up. (Alarm conditions are configurable, see ''WeOS Management Guide''). BLINK Location indicator ("Here I am!"). Activated when connected to IPConfig Tool, or upon request from Web or CLI.
  • Page 27 Mounting This product should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an apparatus cabinet or similar. It is recommended that the DIN-rail is connected to ground. Snap on the product to the DIN-rail according to the figure. Removal This product has an integrated DIN-clip.
  • Page 28: Getting Started

    This product runs Westermo Operating System (WeOS) which provides several management tools that can be used for configuration of the product. • WeConfig tool This is a custom Westermo tool used for discovery of attached Westermo products. • Web Configuration of the product using the web browser.
  • Page 29: Referring Documents

    Referring documents Type Description Document number Management Guide Westermo OS management guide 6101-3201 Factory default on L208-F2G-S2-EX It is possible to set the product to factory default settings by using two straight standard Ethernet RJ-45 cables. 1. Power off the switch and disconnect all Ethernet cables (copper and fibre).
  • Page 30 Dimensions Measurements are stated in millimeters. 96 ±1 52 ±1 92 ±1 6643-22701...
  • Page 31 Westermo • SE-635 35 Stora Sundby, Sweden Tel +46 16 42 80 00 Fax +46 16 42 80 01 E-mail: info@westermo.com www.westermo.com REV. H 6643-22701 2020-12 Westermo Network Technologies AB, Sweden...

Table of Contents