Table 3-1. System Messages - Dell PowerEdge 4200 Installation And Troubleshooting Manual

Dell poweredge 4200 servers: install guide
Hide thumbs Also See for PowerEdge 4200:
Table of Contents

Advertisement

Message
512 MByte mem-
ory limit
exceeded - Mem-
ory above 512
MBytes disabled.
EISA configura-
tion error
EISA configura-
tion NVRAM bad
Embedded server
management error
Embedded server
management firm-
ware download
failed
Incorrect drive
A type - Run
Setup
Incorrect drive
B type - Run
Setup
Invalid CPU
speed detected -
check jumpers
Invalid CPU speed
detected - Check
speed jumpers.
System halted.
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list.
3-2
Dell PowerEdge 4200 Systems Installation and Troubleshooting Guide

Table 3-1. System Messages

Cause
The system supports a
maximum of 512 MB of
memory. Excess mem-
ory is not used.
The EISA data in
NVRAM does not
match the installed
EISA expansion cards.
The EISA jumper may
have been accidentally
installed.
The embedded server
management memory
may be temporarily
corrupted.
The embedded server
management memory
may be temporarily
corrupted.
The installed diskette
drive type does not
match the diskette drive
type in CMOS.
The microprocessor-
speed jumper plug may
be absent or installed on
the wrong pins.
The microprocessor
speed detected is not
valid.
Action
Remove extra DIMMs. See "Removing DIMMs" in Chapter 8.
Verify that any installed EISA expansion cards are properly
seated, and then run the EISA Configuration Utility to verify
that the configuration parameters are correct. See Chapter 5,
"Using the EISA Configuration Utility," in the User's Guide.
Remove the EISA jumper, reboot the system, and restore the
EISA configuration parameters. See Chapter 5, "Using the
EISA Configuration Utility," in the User's Guide.
Turn off the system to clear the memory, and then restart the
system.
Turn off the system to clear the memory, and then restart the
system.
Run the System Setup program to correct the diskette drive
type.
Check the microprocessor speed jumpers. See Table C-1.
Check the microprocessor speed jumpers. See Table C-1.