Warning Messages; Diagnostics Messages; Alert Log Messages From The Dell Hip Program; Scsi Hard-Disk Drive Indicator Codes - Dell PowerEdge 4200 Installation And Troubleshooting Manual

Dell poweredge 4200 servers: install guide
Hide thumbs Also See for PowerEdge 4200:
Table of Contents

Advertisement

Code
1-4-3-1
2-2-3-1
3-2-2-1
4-2-4-4
4-2-4-3
NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list.
W
arning Messages
A warning message alerts you to a possible problem and
asks you to do something before execution continues. For
example, before you format a diskette, a message may
warn you that you may lose all data on the diskette, as a
way to protect against inadvertently erasing or writing
over the data. These warning messages usually interrupt
the procedure and require you to respond by typing y
(yes) or n (no).
NOTE: Warning messages are generated by either the
application programs or the operating system. See
Chapter 4, "Finding Software Solutions," and the docu-
mentation that accompanied the operating system and
application programs.
D
iagnostics Messages
When you run a test group or subtest in the system diag-
nostics, an error message may result. These particular
error messages are not covered in this chapter. Record the
message on a copy of the Diagnostics Checklist found in
Appendix A; then see Chapter 11, "Getting Help," for
instructions on obtaining technical assistance.
Table 3-2. System Beep Codes
Cause
Memory controller failure or DIMM
failure
Unexpected interrupt
Gate A20 failure
Keyboard controller error
(continued)
Action
Check the DIMMs to ensure that they are prop-
erly seated. If the problem persists, run the RAM
Test Group in the system diagnostics. See Chap-
ter 5, "Running the System Diagnostics."
Ensure that all expansion cards are properly
seated, and then reboot the system.
Have the system board replaced. See Chapter 11,
"Getting Help," for instructions on obtaining
technical assistance.
Have the system board replaced. See Chapter 11,
"Getting Help," for instructions on obtaining
technical assistance.
A
lert Log Messages From the
Dell HIP Program
The Dell Hardware Instrumentation Package (HIP)
server management application program generates alert
messages that appear in the simple network management
protocol (SNMP) trap log file. To see the trap log, select
any enterprise under the SNMP trap log icon. (More
information about the Alert Log window and options is
provided in the Dell HIP online help and the Dell HIP
User's Guide.)
Alert log messages consist of information, status, warn-
ing, and failure messages for drive, temperature, fan, and
power conditions. They can assist you with identifying a
problem and may provide you with information to help
you resolve the problem.
S
CSI Hard-Disk Drive Indicator
Codes
The three light-emitting diode (LED) indicators adjacent
to each of the six SCSI hard-disk drive bays provide
information on the status of the SCSI hard-disk drives.
The SCSI backplane firmware controls the drive online
Messages and Codes
3-7

Advertisement

Table of Contents
loading

Table of Contents