Troubleshooting:

Fault
Light on, but motor does
not work.
Light does not work, motor
does not work.
Oil leakage.
Lights not working.
Insufficient suction.
The Range hood inclines.
NOTE:
Any electrical repairs to this appliance must conform to your local, state and federal
laws.Please contact the service centre if in any doubt before undertaking any of the
above.Always disconnect the unit from the power source when opening the unit.
Possible Cause
Fan switch turned off.
Fan switch failed.
Motor failed.
House fuses blown.
Power cord loose or
disconnected.
One way valve and the
outlet are not tightly
sealed.
Leakage from the
connection of chimney and
cover.
Broken/Faulty globes.
The distance between the
range hood and the gas top
is too far.
The fixing screw not tight
enough.
Solution
Select a fan switch
position.
Contact service center.
Contact service center.
Reset/Replace fuses.
Refit cord to power outlet.
Switch power outlet on.
Take down the one way
valve and seal with sealant.
Take chimney down and
seal.
Replace globes as per this
instruction.
Refit the range hood to the
correct distance.
Tighten the hanging screw
and make it horizontal.