Bus interface module for voltage and current

Advertisement

For HDX systems follow these steps:
Make sure the BIM units are all connected to the gauge control box.
With the ignition on, press and hold both switches to enter SETUP. With external switches hold either one
while turning the ignition on. Release the switches when SETUP is shown.
Press and release either switch until BIM is selected. Press and hold either switch to enter BIM setup menu.
Release the switch. A list of the BIM's found should be shown. If NONE FOUND is displayed then check
connections to the BIM-05.
Press and release either switch until BIM-05 is selected.
Press and hold either switch to enter setup for this module.
Release the switch. The menu will show FORMAT, LABEL, WARN LO, WARN HI, CALIBRATE, BACK. Any
menu that does not apply to this BIM will be grey and cannot be selected.
Use either switch to select the option you wish to change, (refer to the HDX manual for specifics).
When you are finished select BACK to return to the BIM selection menu.
When you are finished, select BACK to return to the BIM list menu, select BACK to return to the main menu,
and then select EXIT SETUP to return to normal operation.
With HDX systems the setup can also be done with the Dakota Digital app for Apple and Android devices.
Troubleshooting quick tips:
While the BIM is operating, the dot in the upper left corner of the display will indicate the status. On steady indicates it
is powered up but not receiving any bus activity. Flashing indicates it is communicating on the bus.
To see the sensor and channel status on the BIM display, press and hold the switch. The display will cycle through
three screens. The first will show the sensor input status. Each digit on the display will show the status for one of the
channels. 'E' indicates there is a bus ID conflict on that channel ID. '-' indicates the sender is connected properly. If
the input is turned off the digit will be blank.
The second screen will show the ID assigned to channel 1. The third screen will show the ID assigned to channel 2.
Troubleshooting guide.
Problem
Sensor does not show on
gauge readout.
BIM will not light up at all.
Sensor does not show on
gauge readout.
BIM has a steady dot lit
Gauge lights up, but does
not read correctly.
BIM display shows "88:8"
Possible cause
PWR terminal does not have power.
GND terminal does not have a good
ground.
Module is damaged.
Interface cable is not connected.
Interface cable is loose.
On VHX systems, the BIM display
for this channel is disabled.
Another BIM is set with the same
channel IDs.
Loose connection on sensor wires.
Connector not seated on sensor.
Channel sensor label setup is incorrect. See "Setting sender setup" in the manual.
Wrong input is being used.
Voltage or wiring problem in the
vehicle wiring harness.
Data cable is damaged.
Another module on the bus is damaged Inspect other modules on the data bus.
or connected improperly.
Solution
Connect to a location that has power.
Connect to a different ground location.
Return for service. (see instructions)
Connect the supplied 3.5mm data cable between the BIM unit and
the gauge control box.
Make sure both ends of the cable are seated in securely.
Follow instructions in VHX manual to enable the BIM display screen.
Test module works when connected to control box alone. Change ID's
on one of the modules so each module uses unique IDs.
Inspect and reconnect wires.
Reattach the sensor plug, making sure the locking tab clicks in place.
Use V HI for 0-50V and V LO for 0-5V.
Check wiring harness for loose or damaged wires.
Inspect and replace 3.5mm data cable.
_
_
_