Fluid Supply Line; Fluid Outlet Line - Graco ChemSafe 515 Series Instructions - Parts Manual

Air-operated diaphragm pump
Hide thumbs Also See for ChemSafe 515 Series:
Table of Contents

Advertisement

Installation
Fluid Supply
Supply Line
Line
Fluid
Fluid
Supply
Line
1. Use grounded, flexible fluid hoses (E). See
Ground The System, page
2. If the inlet fluid pressure to the pump is more
than 25% of the outlet working pressure, the
ball check valves will not close fast enough,
resulting in inefficient pump operation. Excessive
inlet fluid pressure also will shorten diaphragm
life. Approximately 3–5 psi (0.02–0.03 MPa,
0.21–0.34 bar) should be adequate for most
materials.
3. For maximum suction lift (wet and dry), see
Technical Data, page
12
10.
31. For best results, always
install the pump as close as possible to the
material source. Minimize suction requirements
to maximize pump performance.
Fluid Outlet
Outlet Line
Line
Fluid
Fluid
Outlet
Line
1. Use grounded, flexible fluid hoses. See
Ground The System, page
2. Install a fluid drain valve (F) near the fluid outlet.
3. Install a shutoff valve (G) in the fluid outlet line.
10,
334794A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chemsafe 515 pt seriesChemsafe 515 uh series

Table of Contents