If pumping toxic fluids, you must vent the exhaust
away from people, animals, food handling areas,
and all sources of ignition. Follow all applicable
codes.
The air exhaust port is 1 in. npt(f). Do not restrict
the air exhaust port. Excessive exhaust restriction
can cause erratic pump operation.
A
Air supply line
B
Bleed-type master air valve (may be
required for your pump installation)
C
Air filter/regulator assembly
D
Master air valve (for accessories)
J
Air inlet port (not visible)
Fluid Supply
Supply Line
Fluid
Fluid
Supply
1. Use grounded, flexible fluid hoses (E). See
Ground The System, page
3A2578E
Tel: 866-777-6060
Fax: 866-777-6383
NOTICE
NOTICE
NOTICE
Line
Line
10.
Springer Pumps, LLC
To provide
provide a a a remote
remote exhaust:
exhaust:
To
To
provide
remote
exhaust:
1. Remove the muffler (U) from the pump air
exhaust port (K).
2. Install a grounded air exhaust hose (S) and
connect the muffler to the other end of the hose.
The minimum size for the air exhaust hose is 1
in. (26 mm) ID. If a hose longer than 15 ft (4.57
m) is required, use a larger diameter hose. Avoid
sharp bends or kinks in the hose.
3. Place a container (T) at the end of the air exhaust
line to catch fluid in case a diaphragm ruptures.
If the diaphragm ruptures, the fluid being pumped
will exhaust with the air.
K
Air exhaust port
S
Grounded air exhaust hose
T
Container for remote air exhaust
U
Muffler