Fluid Supply Line; Fluid Outlet Line - Graco ChemSafe 307 Instructions-Parts List Manual

Air-operated diaphragm pump
Table of Contents

Advertisement

Installation
Fluid
Fluid Supply
Fluid
Supply Line
Supply
1. Use grounded, flexible fluid hoses (E). See
Ground The System, page
2. If the inlet fluid pressure to the pump is more
than 25% of the outlet working pressure, the
ball check valves will not close fast enough,
resulting in inefficient pump operation. Excessive
inlet fluid pressure also will shorten diaphragm
life. Approximately 3–5 psi (0.02–0.03 MPa,
0.21–0.34 bar) should be adequate for most
materials.
3. For maximum suction lift (wet and dry), see
Technical Data, page
12
Springer Pumps, LLC
Telford, PA 18969
Line
Line
10.
31. For best results, always
Tel: 866-777-6060 / Int'l: 215-949-2900
Fax: 866-777-6383 / Int'l: 215-721-1296
install the pump as close as possible to the
material source. Minimize suction requirements
to maximize pump performance.
Fluid Outlet
Outlet Line
Line
Fluid
Fluid
Outlet
Line
1. Use grounded, flexible fluid hoses. See
Ground The System, page
2. Install a fluid drain valve (F) near the fluid outlet.
3. Install a shutoff valve (G) in the fluid outlet line.
10,
334793B
shop.springerpumps.com
info@springerpumps.com

Advertisement

Table of Contents
loading

Table of Contents