Electrical Characteristics - Teltonika FMC640 Quick Manual

Professional lte/gnss terminal
Hide thumbs Also See for FMC640:
Table of Contents

Advertisement

Electrical characteristics

Table 5 Electrical characteristics
Characteristic description
Supply Voltage
Supply Voltage (Recommended Operating
Conditions)
Digital output (Open drain grade)
Drain current (Digital Output OFF)
Drain current (Digital Output ON,
Recommended Operating Conditions)
Static Drain-Source resistance (Digital Output
ON)
Digital Input
Input resistance (DIN1)
Input resistance (DIN2)
Input resistance (DIN3)
Input resistance (DIN4)
Input voltage (Recommended Operating
Conditions)
Input Voltage threshold (DIN1, DIN2, DIN3,
DIN4)
Value
Min.
Typ.
Max.
Unit
+10
+30
V
120
µA
0.5
A
400
300
mΩ
15
kΩ
15
kΩ
15
kΩ
15
kΩ
Supply
0
V
voltage
7.5
V
13
Analog input
Input Voltage (Recommended Operating
Conditions), Range 1
Input resistance
Input Voltage (Recommended Operating
Conditions), Range 2
Input resistance
1-WIRE
Supply voltage
Output inner resistance
Output current (U
> 3.0 V)
OUT
Short circuit current (U
> 0 V)
OUT
CAN interface
Internal terminal resistors CAN bus
Differential input resistance
Recessive output voltage
Differential output voltage
Common mode input voltage
0
+10
V
120
kΩ
0
+30
V
147
kΩ
+3.3
+3.9
V
7
30
mA
75
mA
120
19
30
52
kΩ
2
2.5
3
V
0.5
0.7
0.9
V
-30
30
V
FMC640| Wiki