Download Print this page

Dakota Digital BIM-01-2-AEM Quick Start Manual page 3

Bus interface module for aem engine management

Advertisement

HDX setup (Can also be completed using the Bluetooth app):
Using speed from the BIM-01-2
With ignition on. Press and hold both switches to enter SETUP.
Press and release either switch until SPEED is selected. Press and hold either switch to enter SPEED menu.
Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu.
Press and release either switch unit BIM is displayed. Press and hold either switch to select BIM.
Using RPM from the BIM-01-2
Press and hold both switches to enter SETUP.
Press and release either switch until TACH is selected. Press and hold either switch to enter TACH menu.
Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu.
Press and release either switch until CYLINDER is displayed. Press and hold either switch to select CYLINDER.
Press and release either switch until BIM is displayed. Press and hold either switch to select BIM.
Using engine temperature from the BIM-01-2
Press and hold both switches to enter SETUP.
Press and release either switch until WATER is selected. Press and hold either switch to enter WATER menu.
Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu.
Press and release either switch until BIM is displayed. Press and hold either switch to select BIM.
Using oil pressure from the BIM-01-2 (if available)
Press and hold both switches to enter SETUP.
Press and release either switch until OIL is selected. Press and hold either switch to enter OIL menu.
Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu.
Press and release either switch until BIM is displayed. Press and hold either switch to select BIM.
VFD/VHX/HDX wiring tip:
When connecting to a VFD or VHX display system you can easily get power and ground from the control box RESERVED+
(FUEL+) and FUEL- terminals. These terminals are normally not used. Connect the BIM-xx-1 adapter harness RED wire to the
RESERVED+ (FUEL+) terminal and connect the BIM-xx-1 adapter harness BLACK wire to the FUEL- terminal.
Troubleshooting quick tips:
While the BIM is operating, the dot in the upper left corner of the display will indicate the status. On steady indicates it is
powered up but not receiving any BIM bus activity. Flashing indicates it is communicating on the BIM bus.
If the display shows "" then it is scanning to try and communicate with the AEM system bus but cannot get an answer. To see
the sensor and channel status on the BIM display, press and hold the switch. The display will cycle through several screens.
The first will show the bus type ("" AEM). The next screens will indicate which (if any) extended data is available: "" for
intake/manifold temp, "" for engine oil pressure, "" for trans fluid temp.
To set or change the ID number:
The ID will not normally need to be changed. The fuel PSI and A/F ratio readings both use bus ID's so if you have other BIM
units connected along with this one there is a chance of ID conflicts. This can easily be resolved. If fuel PSI or A/F ratio is not
showing up in the BIM setup menu on your system you may need to resolve an ID conflict. The following procedure will allow the
BIM-01-2 to automatically select a new, unused ID.
Hold the switch on BIM while turning the key on. The BIM will show the current software code.
Release the switch.
Press and release the switch until "" is shown on the display.
Press and hold. "" will be shown while the BIM is scanning the bus for other BIM units.
When you see "" shown on the display release the switch.
The BIM unit will now go back to normal operation.
***Intake/manifold air temp, Fuel PSI, boost and A/F ratio will be displayed in the group screens if activated through the displays>>group set menu
setup.
MAN #650617

Advertisement

loading