System Setup:
AEM system setup
This unit is plug-and-play. Attach the included Y-harness to your AEMnet device. No further setup is required.
AEM boost reading
This module is programmed to monitor boost(PSI). This is done by monitoring the MAP sensor. To ensure accuracy we calibrate
the baseline barometric pressure from the MAP sensor when the device receives power and the engine is off. To enable this
feature, you must enable the  (boost) option through the setup menu. With the unit off, press and hold the button on the BIM.
Cycle the ignition to the on position then release the button. Press and release the button until  (boost) is displayed. Press
and hold to enter the menu. Press and release the button until  is shown. Press and hold to select.
Display data usage
The following readings can each be used in place of dedicated sending units to the gauge control unit. These are individually
selectable in the display system gauge setup menus.
*Some gauge features require a minimum software revision or higher to be supported:
VHX
VFD3
VFD3X
VHX/VFD Setup:
Using speed from the BIM-01-2
Hold the SW1 switch from the gauge system control box while turning the key on. The message display should show
SETUP.
Release SW1. The message display should show SPEED.
Press and hold SW1. The message display should show SENDER. Release SW1.
Press and release SW1 until BUS is displayed.
Press and hold SW1 until DONE is displayed.
Using RPM from the BIM-01-2
Hold the SW1 switch from the gauge system control box while turning the key on. The message display should show
SETUP.
Release SW1. Press and release SW1 until TACH is displayed.
Press and hold SW1. The message display should show T CAL or ENGINE. Release SW1.
Press and release SW1 until BUS is displayed.
Press and hold SW1 until DONE is displayed.
Using engine temperature from the BIM-01-2
Hold the SW1 switch from the gauge system control box while turning the key on. The message display should show
SETUP.
Release SW1. Press and release SW1 until WATER is displayed.
Press and hold SW1. The message display should show SENDER. Release SW1.
Press and release SW1 until BUS F or BUS C is displayed depending on your unit choice.
Press and hold SW1 until DONE is displayed.
Using oil pressure from the BIM-01-2 (if available)
Hold the SW1 switch from the gauge system control box while turning the key on. The message display should show
SETUP.
Release SW1. Press and release SW1 until OIL is displayed.
Press and hold SW1. The message display should show SENDER. Release SW1.
Press and release SW1 until BUS is displayed.
Press and hold SW1 until DONE is displayed.
***Intake/manifold air temp, Fuel PSI, boost and A/F ratio will be displayed in the message center if activated through the display menu setup.