Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pressu-
res.

Installation Instructions

The fitting must be installed, flushed and tested after
the valid norms.
If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart®
(flow limiter) located behind the aerator can be
removed.
Technical Data
This mixer series-produced with EcoSmart®
(flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.

English
Symbol description
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
Assembly see page 31
To adjust the hot water limiter on single lever
mixers, please see page 32. No adjustment
is necessary when using a continuous flow
water heater.
Do not use silicone containing acetic acid!
Dimensions (see page 33)

Flow diagram

(see page 33)
with EcoSmart®
without EcoSmart®
Spare parts (see page 35)