Download Print this page

Installation Instructions - Hans Grohe Tecturis E 110 Fine CoolStart 73020 9 Series Instructions For Use/Assembly Instructions

Advertisement

Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The drain valve may only be installed in basins with
an overflow opening.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Water escaping in area of swivel
spout
Water escaping at the threaded base - connection hoses not completely
Hot water temperature too low
2
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
Cause
- Aerator calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
screwed into basic body
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
Assembly (see page 4)
English
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 6)
Flow diagram (see page 7)
Spare parts (see page 8)
XX = Colors
00 = Chrome Plated
14 = Brushed Bronze
67 = Matt Black
82 = Brushed Nickel
Special accessories (order as an extra)
• flange Hot water limiter (see page 8)
Cleaning (see page 5)
Operation (see page 7)
Hansgrohe recommends not to use as drinking water the
first half liter of water drawn in the morning or after a
prolonged period of non-use.
Remedy
- Clean aerator, replace as necessary
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter

Advertisement

loading

This manual is also suitable for:

Tecturis e 110 fine coolstart 73021 3 seriesTecturis e 240 fine coolstart 73070 9 seriesTecturis e 240 fine coolstart 73072 3 series