Section 3: Operation

Light Tower Setup

E
D
B
DANGER
High Voltage. Verify area above unit is clear
of overhead wires and obstructions. Contact
with high-voltage power lines will result in
death or serious injury.
WARNING
Do not set up the unit if high winds
> 60 mph
> 60 mph
are expected. High winds can cause the
unit to tip or fall, causing severe injury
or machine damage.
1. For maximum light coverage, position the unit at
ground level or in a spot higher than the area being
illuminated.
NOTE: The mast extends up to 30 ft (9.14 m).
2. See
Figure
3-1. Place the unit on firm ground that
is relatively flat (less than 5° slope), and then block
the wheels to keep it from moving (A). This will
make it easier to level the unit.
3. Pull the locking pin on the tongue jack (B) and
rotate the jack 90°. Install the locking pin. Rotate
Owner's Manual for MLT Light Tower
H
C
D
G
E
Figure 3-1. Set Up Outriggers and Jacks
(000260a)
(000297)
J
H
F
DETAIL C
A
the jack handle clockwise to raise the trailer tongue
off the towing vehicle.
4. A grounding stud (C) is located on the frame of the
trailer at the base of the mast post. For grounding
requirements, follow National Electrical Code
(NEC), state, and local guidelines.
5. Pull locking pins (D) on the outriggers (E) and pull
each outrigger out until the spring loaded locking
pin snaps back into place. Pull the locking pin on
each outrigger jack and rotate each jack 90° so the
jack pad is facing down. Install the locking pin.
6. Pull the locking pin on the rear jack (F) and rotate it
90º. Install the locking pin. Turn the jack handle
clockwise to start leveling the trailer.
7. Rotate each jack handle clockwise to start leveling
the trailer. Adjust all four jacks by rotating their
handles clockwise until they are firmly in contact
with the ground (G).
8. Before raising the mast, it may be necessary to
adjust the lamps. The lamps may be adjusted up,
down, left or right by loosening the wing nuts on the
trunnion (H) and aiming the lamps in the desired
direction. Tighten the hardware completely and
verify the lamps are connected to junction box (J).