Section 3:Operation; Light Tower Setup - Generac Power Systems MAGNUM MLT4060DOTM Owner's Manual

Light tower
Table of Contents

Advertisement

Section 3: Operation

Light Tower Setup

E
D
B
C
DANGER
High Voltage. Verify area above unit is clear
of overhead wires and obstructions. Contact
with high-voltage power lines will result in
death or serious injury.
WARNING
Do not set up the unit if high winds
> 60 mph
> 60 mph
are expected. High winds can cause the
unit to tip or fall, causing severe injury
or machine damage.
1. For maximum light coverage, position the unit at
ground level or in a spot higher than the area being
illuminated by the lamps.
NOTE: The mast extends up to 30 ft (9.14 m).
Owner's Manual for MLT Light Tower
E
D
G
Figure 3-1. Set Up Outriggers and Jacks
(000260a)
(000297)
H
F
A
NOTE:
See
Flagger
instructions if intending to use the light tower as flagger
station lighting.
2. See
Figure
3-1. Place the unit on firm ground that
is relatively flat (less than 5° slope), and then block
the wheels to keep it from moving (A).This will
make it easier to level the unit.
3. Pull the locking pin on the tongue jack (B) and
rotate the jack 90°until the spring loaded pin snaps
back into place. Rotate the jack handle clockwise
to raise the trailer tongue off the towing vehicle.
4. A grounding stud (C) is located on the frame of the
trailer near the trailer tongue. For grounding
requirements, follow the National Electrical Code
(NEC), state, and local regulations.
5. Pull the locking pins (D) on the outriggers (E) and
pull each outrigger out until the spring loaded
locking pin snaps back into place. Pull the locking
pin on each outrigger jack and rotate each jack 90°
Operation
DETAIL C
DETAIL D
DETAIL G
DETAIL H
004606
Station
Setup
for
setup
11