Product Description; Technical Data - Dea REV Series Operating Instructions And Warnings

Hide thumbs Also See for REV Series:
Table of Contents

Advertisement

2 PRODUCT DESCRIPTION

Models and contents of the package
The name REV identifies a series of electromechanical operators for sliding gates with different features as to motor and control
board power supply voltage, capacity, mechanical adjustment of force, electronic clutch and built-in limit switch. All automated models
involve the use of advanced control units (NET series) equipped with anti-crushing sensor, built-in 433 MHz radio receiver, speed control
and slow down in opening and closing. The REV models are intended primarily for residential / condominium and Semi-intensive/inten-
sive use depending on the duty cycle foreseen for the automation.
REV is completed by a set of accessories listed in the "PRODUCT ACCESSORIES" table (page I-7).
REV is composed of a mechanical gear motor which rotates the driving gear; This gear, coupled to the rack properly installed on the
gate, converts the circular motion of the gear motor into rectilinear motion thus allowing the movement of the gate on its own guide.
Inspect the "Contents of the Package" (Pic. 1) and compare it with your product for useful consultation during assembly.
Transport
REV is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all information
that may be provided on the same box for storage and handling.

3 TECHNICAL DATA

Motor power supply voltage (V)
Absorbed power (W)
Max Thrust (N)
Work cycle (leaf L=8m)
Maximum n° of operations in 24
hour (leaf L=8m)
Built-in capacitor (µF)
Operating temperature range (°C)
Motor thermal protection (°C)
Opening speed (m/min)
Weight of product with package (Kg)
Sound pressure emitted (dBA)
Protection degree
NET24N
Power supply (V)
Rated power transformer (VA)
Fuse F1 (A) (transformer)
Batteries
Fuse F2 (A) (batteries input)
24V operators outputs
Warning: The above values are calculated by taking the maximum power
supplied by the respective processors. In absolute terms, the maximum
current for each output should not exceed 10A when using a single motor
and 7A when using 2 motors.
Auxiliaries power supply output
Safety devices power supply output
"Warning" output
Electric lock output
Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
OPERATOR
REV220 - REV220/M -
REV220/IB
900
up to 1000 Kg
up to 1400 Kg
up to 1000 Kg
270
up to 1400 Kg
220
14
CONTROL BOARD
230 V ~ ±10% (50/60 Hz)
250 VA (230/22V)
2A
2x 12V 1,3A
15A
1x 10A
24 V
(24V_AUX + 24V_ST =
max 200mA)
24 V
max 15 W
24V
max 5W or max
1 art. 110
24 V
max 15W
-20÷50 °C
433,92 MHz
HCS fix-code - HCS rolling
code - Dip-switch
100
REV220/RF - REV220/RFM
- REV220/RF/IB
230 V ~ ±10% (50/60 Hz)
500
1200
27 cycles/hour
22 cycles/hour
300
250
12,5
-20÷50 °C
150 °C
10
18
< 70
IPX4
NET230N
Power supply (V)
Fuse F2 (A)
Fuse F1 (A)
230V operators outputs
Auxiliaries power supply output
Safety devices power supply output
"Warning" output
Electric lock output
230V Flashing light output
24V Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
REV24/F - REV24/M -
REV24/IB
24 V
250
450
36 cycles/hour
31 cycles/hour
300
250
-
-
12
230 V ~ ±10% (50/60 Hz)
5A
160mA
2x 500W (or 1x 600W)
24 V ~
(24V_AUX + 24V_ST
= max 200mA)
24V
230 V ~ max 150W
max 1 art. 110 or 24V
output max 5W configurable
230 V ~ max 40W
24 V
max 100mA (for led
flashing light) art. LED24AI or
open gate warning light/courtesy
light
-20÷50 °C
433,92 MHz
HCS fix-code - HCS rolling code -
Dip-switch
100
EN-3

Advertisement

Table of Contents
loading

Table of Contents