System Monitoring Features; Main System Monitoring; Firmware (Fw) And Management Software Suite; Audible Alarms - Infortrend EonStor GSe Pro 1000 Series Hardware Manual

Hide thumbs Also See for EonStor GSe Pro 1000 Series:
Table of Contents

Advertisement

System Monitoring Features

There are a number of monitoring approaches that provide the operating status of
individual components.

Main System Monitoring

The system is aware of the status of components including those of:
 Controller (presence, voltage and thermal readings)
 PSU
 Cooling module
 Service (the Service signal to specify a specific enclosure)
 Disk drives
Cooling Module Speed Adjustment:
If any of the detected temperature readings breaches the temperature threshold, the
firmware running on the managing system automatically raises the rotation speed of
all cooling fans.

Firmware (FW) and Management Software Suite

The firmware (FW) is preloaded and is used to configure the system. The FW can be
accessed through the management software, a browser-based graphical user
interface (GUI) software that can be installed on a local/remote computer and
accessed via the network. The manager communicates with the array via the
connection of the existing host links or the Ethernet link to the array's Ethernet port.

Audible Alarms

The system comes with audible alarms that are triggered when certain active
components fail or when certain controller or system thresholds are exceeded.
Whenever you hear an audible alarm, it is imperative that you determine the cause
and rectify the problem immediately.
Event notification messages indicate the completion or status of array configuration
tasks and are always accompanied by two or three successive and prolonged beeps.
The alarm can be turned off using the
mute button
on the front panel.