6 Maintenance

6.7.2 Shaft and sleeve inspection

Inspection criteria
Inspect the shaft and sleeve according to this criteria:
• Thoroughly clean the shaft and sleeve.
• Thoroughly clean the coverplate seal cavity.
• Inspect the surface for damage such as pitting, corrosion, nicks, and scratches.
Replace these parts if they are damaged.

6.8 Dimensions

Pump with mechanical seal on the shaft
Figure 20: Cross section
Figure 21: Impeller wear ring
Figure 23: Dowel pin location at parting line
38
G&L Pumps Series A-C 8100 Base Mounted Centrifugal Pump INSTRUCTION MANUAL
Figure 22: Balanced mechanical seal