5 Commissioning, Startup, Operation, and Shutdown

5.1.6 Freezing protection

NOTICE:
Do not expose an idle pump to freezing conditions. Drain all liquid that is inside the pump
and connected pipes. Failure to do so can cause liquid to freeze and damage the pump.
Pumps that are shut down during freezing conditions should be protected by one of the
following methods:
• Drain the pump; remove all liquids from the casing.
• Keep fluid moving in the pump and insulate or heat the pump to prevent freezing.

5.1.7 Change the rotation

The pump can be operated left hand or right hand when viewed from the pump end of
the pump. If you wish to reverse the suction and discharge nozzles, this can be
accomplished with the same pump as follows. IMPORTANT: Refer to the disassembly and
assembly procedures in this manual for proper disassembly and assembly techniques.
1. Remove the impeller from the shaft, turn it 180° and replace it on the shaft. Note:
Impeller can only come off from the outboard end.
2. With the rotating element out of the casing, remove the casing from the bedplate and
turn 180°.
3. Set the rotating element back in the casing and reassemble the pump.
4. Reassemble pump and realign the coupling as called for in the alignment procedures.
5. The rotation of the motor must be changed by switching the motor leads.
2
Figure 17: Correct relationship of impeller and casing
1. Rotation
2. Discharge
3. Suction
4. Left-hand rotation viewed from the pump end
5. Right-hand rotation viewed from the pump end
26
– The impeller and casing are in the same relationship to each other as they were
originally. The shaft and motor are also in the same relationship to each other as
they were originally.
WARNING:
Never operate a pump without a properly installed coupling guard.
Personal injury will occur if you run the pump without a coupling guard.
– Unless the motor rotation is reversed, the impeller will run backward.