Coupler Limitations; Piping Checklists; Piping Checklist - Xylem G&L A-C 8100 Series Instruction Manual

Base mounted centrifugal pump
Table of Contents

Advertisement

4 Installation

4.2.7 Coupler limitations

Brand
Suitable for
variable speed
application
TB Wood's
Sure-Flex
Yes
(Neoprene
sleeve)
TB Wood's
Sure-Flex
No
(Hytrel Sleeve)

4.3 Piping checklists

4.3.1 Piping checklist

WARNING:
• The heating of water and other fluids causes volumetric expansion. The associated
forces can cause the failure of system components and the release of high-
temperature fluids. In order to prevent this, install properly sized and located
compression tanks and pressure-relief valves. Failure to follow these instructions can
result in serious personal injury or death, or property damage.
• Avoid serious personal injury and property damage. Make sure that the flange bolts
are adequately torqued.
• Never force piping to make a connection with a pump.
20
Minimum
Allowable installation misalignment limits
recommended
Coupler size
speed
3
4
5
6
7
8
50% of full
speed
9
10
11
12
13
14
3
4
5
6
7
8
N/A
9
10
11
12
13
14
G&L Pumps Series A-C 8100 Base Mounted Centrifugal Pump INSTRUCTION MANUAL
Parallel (inch) Angular (inch
or degree)
0.010
0.035
0.010
0.043
0.015
0.056
0.015
0.070
0.020
0.081
0.020
0.094
0.025
0.109
0.025
0.128
0.032
0.151
0.032
0.175
0.040
0.195
0.045
0.242
0.010
0.016
0.012
0.020
0.015
0.025
0.017
0.028
0.020
0.032
0.022
0.037
0.025
0.042
0.030
0.050
0.035
0.060
Y Dimension
Maximum
(inch)
temperature
1.188
1.500
1.938
2.375
2.563
2.938
200°F
3.500
4.063
4.875
4.688
6.688
7.750
2.375
2.563
2.938
250°F
3.500
4.063
4.875
5.688
6.625
7.750
Minimum
temperature
–0°F
–65°F

Advertisement