Care and Maintenance
Always keep the drill rig clean, especially the column with the toothing and
the 4 sliding pieces in the machine holder.
In order to allow the free movement of the pinion shaft, it should be slightly
lubricated.
In order to achieve a good performance of the drill rig, the 4 sliding pieces in
the machine holder have to move along the column without slackness.
Attention:
After every tenth drilling you should check if the sliding pieces have got loose-
fitting due to drilling vibration.
If the position should have changed, it can be readjusted as follows:
behavior at malfunction
Turn off the machine at malfunction and disconnect from the
main supply. Operations on the electrical system of the
machine can be executed by a specialist only.
Trouble shooting
malfunction
Drill unit has to much
play (vibration)
possible cause
stand has been loose
guidance has to much play
thrust piece worn
Loosen the counter nut on the Allen
screw by means of an jaw wrench
SW 17
Adjust the Allen screws and the
position of the thrust piece to the
column by means of a hex head
wrench SW 8.
Tighten the counter nut again and
check whether the carriage moves
easily on the column.
repair
adjust the wing nut
adjust guidance (see above)
replace the thrust piece