Mitsubishi Electric PUZ-M200YKA Service Manual page 63

Split-type, heat pump air conditioners
Hide thumbs Also See for PUZ-M200YKA:
Table of Contents

Advertisement

(5) Operation data during emergency operation
During emergency operation, no communication is performed with the indoor unit, so the data items needed for operation
are set to the following values:
Operation data
Intake temperature (TH1)
Indoor pipe temperature (TH2)
Indoor 2-phase pipe temperature (TH5)
Set temperature
Outdoor liquid pipe temperature (TH3)
Outdoor discharge temperature (TH4)
Outdoor comp. surface temperature (TH33)
Outdoor 2-phase pipe temperature (TH6)
Outdoor ambient temperature (TH7)
Temperature difference code
(room temperature - set temperature) (∆Tj)
Discharge superheat (SHd)
Sub-cool (SC)
*1. If the thermistor temperature data is normal (not open/short), that data is loaded into the control as valid data.
When the unit enters emergency operation and TH values are mismatched, set the thermistors to open/short.
And the unit runs emergency operation with the values listed above.
*2. If one thermistor is set to open/short, the values for SHd/SC will be different from the list above.
[Example] When liquid temperature thermistor (TH3) has an open or short circuit.
Thermistor
TH3
TH6
Regard normal figure as effective data.
TH4/TH33
Regard normal figure as effective data.
TH5
TH2
Discharge superheat (SHd)
Cooling = TH4(or TH33)−TH6 = Tc−Ta
Heating = TH4(or TH33)−TH5 = Td−50
Degree of subcooling (SC)
Cooling = TH6−TH3 = Ta−45
Heating = TH5−TH2 = 50−45 = 5:
OCH737
COOL
27:
5:
5:
25:
45:
80:
50:
35:
5
30:
5:
HEAT
COOL
5:
45:
Tb
Ta
Td
Tc
5:
50:
45:
5:
Operation mode
HEAT
20.5:
45:
50:
22:
(*1)
5:
(*1)
80:
(*1)
5:
(*1)
7:
5
(*2)
30:
(*2)
5:
63
Remarks