Download Print this page

Differential Temperature - Kane 457 Quick Reference Manual

Hide thumbs Also See for 457:

Advertisement

When complete adjust the gas pressure if necessary then press
stabilisation period...
STABIL'N
P1
20.00
mbar
TIME
When complete adjust the gas pressure if necessary then press
test...
TIGHTN'S
P1
20.33
P2
20.33
TIME
When complete the display will show...
LOG
P1
20.33
P2
20.26
PRINT
Note:
The analyser's memory can store up to 20 tightness tests. Tightness tests are logged
automatically therefore the tightness section of the memory will be full after the 20
tightness test is complete. Before the 21
tightness section of the memory must be cleared. To do this select MENU / REPORT /
TIGHTN'S / DEL ALL / YES then press
6.

DIFFERENTIAL TEMPERATURE

Select "Diff Temp" to measure flow, return and differential temperatures
DIFF TEMP display
TEMP
T1
C
T2
C
T
13.1
C
Press SEND to print a differential temperature test. (Also sends to PC if Bluetooth fitted).
Hold SEND for 2+ seconds to log a differential temperature report.
-
Stabilisation display.
-
Real time pressure reading
59
-
Stabilisation default time is 1 minute. Can be changed via "Menu".
-
Tightness test display.
-
Pressure at start of tightness test
-
Real time pressure reading
119
-
Tightness default time is 2 minute. Can be changed via "Menu".
06
-
Let-by and tightness test are automatically stored as a log number
-
Pressure at start of tightness test
-
Pressure at end of tightness test
-
The test can be printed immediately or later from the memory
-
Pump automatically switches off when dial is moved to Diff Temp
60.1
-
Use the T1 connection for the flow temperature sensor
47.0
-
Use the T2 connection for the return temperature sensor
-
Real time temperature difference
st
tightness test can be performed the
.
to start the
to start the tightness
th

Advertisement

loading