Checking And Cleaning Of Electrical Wiring And Battery Cables; Checking Movable Parts; Every 50 Hours; Lubricating Grease Fittings - Kubota L2501 Operator's Manual

Hide thumbs Also See for L2501:
Table of Contents

Advertisement

BChecking and Cleaning of Electrical
Wiring and Battery Cables
To avoid personal injury or death:
A A loosened terminal or connector, or damaged
wire may affect the performance of electrical
components or cause short circuits. Leakage
of electricity could result in a fire hazard, a
dead
battery
components.
A Replace
damaged
promptly.
A If a fuse blows soon after replacement, DO NOT
USE A LARGER THAN RECOMMENDED FUSE
OR BYPASS THE FUSE SYSTEM.
A Many wiring connections are protected by
waterproof plugs, plug and unplug these
connections carefully and make sure they are
sealed correctly after assembly.
A Accumulation of dust, chaff and spilled fuel
deposits around the battery, electrical wiring,
engine or exhaust system are fire hazards.
CLEAN THESE AREAS BEFORE STARTING
WORK.
To avoid premature electrical malfunctions DO
NOT APPLY high pressure water directly to
battery,
wiring,
components or instrument panel.
Inspect the following regularly:
1. Check wiring for chafed or cracked insulation.
2. Check wiring harness clamps. Replace if necessary.
3. Check connectors and terminals for looseness,
contamination
or
connections.
4. Check instrument panel for correct operation of
switches and gauges.
Consult your KUBOTA Dealer regarding maintenance,
diagnosis and repair.
BChecking Movable Parts
If any of the movable parts, such as levers and pedals, is
not smoothly moved because of rust or sticky material, do
not attempt to force it into motion.
In the above case, remove the rust or the sticky material,
and apply oil or grease on the relevant spot.
Otherwise, the machine may get damaged.
or
damage
to
electrical
wires
or
connections
connectors,
electrical
overheated
(discolored)

EVERY 50 HOURS

BLubricating Grease Fittings
Apply a small amount of multipurpose grease to the
following points every 50 hours:
If you operated the machine in extremely wet and muddy
conditions, lubricate grease fittings more often.
(1) Grease fitting (Knuckle shaft)[RH, LH]
When apply grease to forward front axle support, remove
the breather plug and apply grease until grease overflows
from breather plug port.
After greasing reinstall the breather plug.
(1) Grease fitting (Front axle support)
(2) Breather plug
PERIODIC SERVICE