5.4.5
Description
Setup
Rugby 840, Applications

Facades

The Rugby 840 and the Rod Eye 180 Digital Receiver create a vertical plane of laser
light that is aligned to the building and acts as a constant reference for facade
installations.
Mounting the facade adapter brackets
004808_002
Step
Description
1.
Mount the facade adapter brackets to the side of the building in locations
where it is desired to have a laser and receiver setup.
Laser setup
004809_001
Step
Description
1.
Mount the Rugby to the clamp and then the clamp to the facade adapter
bracket.
2.
Turn on the Rugby.
The laser beam will automatically point downwards so that the laser and the
clamp can be positioned at the desired distance from the building's surface.
3.
Set the head rotation to the fastest speed (10 rps).