Procom ML060HPA Owner's Operation And Installation Manual

Procom ML060HPA Owner's Operation And Installation Manual

Infrared vent-free propane/lp gas space heater

Advertisement

OWNER ' S OPERATION AND INSTALLATION MANUAL
ML060HPA ML100HPA

Table of Contents

Important Safety Information.................................2
Product Features.....................................................3
Proper Ventilation & Fresh Air..............................4
Installation................................................................6
Operating Your Heater............................................10
Cleaning & Maintenance.......................................13
Trouble Shooting...................................................14
Specifications..........................................................17
Parts List..................................................................19
WARNING: If the information in this
manual is not followed exactly, a f i r e o r
e x p l o s i o n m a y r e s u l t causing property
damage, personal injury, or loss of life.
WARNING: This is an unvented gas-
fired heater. It uses air (oxygen) f r o m t h e
r o o m i n w h i c h i t i s installed. Provi-
sions for adequate combustion and ventila-
tion air must b e p r o v i d e d . R e f e r t o A i r
F o r Combustion and Ventilation section on
page 4 of this manual.
Continental Appliance Inc.
5 Musick
Irvine
CA 92618
TOLL-FREE NUMBER: 1-877-886-5989
ML100TPA
4600 Highlands
Parkway S.E. Suite# D/E
Smyrna GA 30080
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately
call
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
q u a l i f i e d
i n s t a l l e r , s e r v i c e
supplier.
WA R N I N G :
adjustment, alteration, service or mainte-
nance can cause injury or property damage.
Refer to this manual for correct installation and
operational procedures. For assistance or
additional information consult a qualified
installer, service agency, or gas supplier.
This appliance may be installed in an aftermar-
ket*
permanently
(mobile) home, where not prohibited by local
codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM
HEATERS
Water vapor is a by-product of gas combustion.An
unvented room heater productes approximately one (1)
ounce (30ml) of water for every 1,000 BTU's (.3KW's) of
gas input per hour. Refer to page 3.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
Installer: Please leave these instructions with the
consumer.
Consumer: Please retain these instructions for
future use.
INFRARED VENT-FREE
PROPANE/LP GAS
SPACE HEAT ER
your gas supplier from a
a g e n c y
I m p r o p e r
i n s t a l l a t i o n ,
located, manufactured
o r
g a s

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ML060HPA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Procom ML060HPA

  • Page 1: Table Of Contents

    OWNER ’ S OPERATION AND INSTALLATION MANUAL ML060HPA ML100HPA Table of Contents Important Safety Information...2 Product Features...3 Proper Ventilation & Fresh Air...4 Installation...6 Operating Your Heater...10 Cleaning & Maintenance...13 Trouble Shooting...14 Specifications...17 Parts List...19 WARNING: If the information in this...
  • Page 2: Important Safety Information

    IMPORTANT SAFETY INFORMATION WARNINGS I M P O R TA N T: R e a d t h i s owner’s manual carefully and c o m p l e t e l y b e f o r e t r y i n g assemble, operate, or service this...
  • Page 3: Product Identification

    Figure 1- Vent-Free Propane/LP Gas Heater SAFETY DEVICE A standard requirement for all vent-free room heaters. This heater has a pilot with an Oxygen Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor.
  • Page 4: Proper Ventilation & Fresh Air

    FRESH AIR FOR COMBUSTION AND VENTILATION WARNING: This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion v e n t i l a t i o n a i r . R e a d f o l l o w i n g i n s t r u c t i o n s...
  • Page 5: Air For Combustion And Ventilation

    3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Gas water heater* Gas furnace Vented gas heater Gas Fireplace logs Other gas appliances* + Total *Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
  • Page 6: Installation

    WARNING: Never install " the heater in a bathroom(Models ML100HPA and ML100TPA , only ML060HPA is allowed in a bathroom. Check local codes.) in a recreational vehicle. where curtains, furniture. as a fireplace insert. in high traffic areas.
  • Page 7: Fastening Heater To Wall

    WARNING: Maintain the minimum clearances shown F i g u r e 4 . y o u c a n , provide greater clearances from floor, ceiling, and joining wall. Figure 4 -Mounting clearances As Viewed From Front of Heater FASTENING HEATER TO WALL Mounting Bracket The mounting bracket is located...
  • Page 8 Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method For attaching mounting bracket to wall studs 1. Drill holes at marked locations "...
  • Page 9: Connecting To Gas Supply

    CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: This appliance " requires a 3/8 NPT (National Pipe T h r e a d ) i n l e t c o n n e c t i o n to the pressure regulator.
  • Page 10: Checking Gas Connections

    INSTALLATION CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints.
  • Page 11: Manual Lighting Procedure

    Manual Control Models: ML060HPA,ML100HPA LIGHTING INSTRUCTIONS STOP! Read safety information on the side of heater. 2. Check that gas supply to heater is on. 3. Push in gas control knob slightly and turn clockwise the OFF position. ( see Figures 16 & 17) Wait five (5) minutes to clear out any air.
  • Page 12 THERMOSTAT MODEL ML100TPA FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 13: Operating Heater

    OPERATING HEATER Continued MANUAL LIGHTING PROCEDURE Remove lower front panel (see Figure 7 page 7). Follow steps through 5 under Lighting Instructions on page12. With control knob pressed in, strike match. Hold match to pilot until pilot lights. Keep control knob pressed in for 30 seconds after lighting pilot.
  • Page 14: Troubleshooting

    Note : troubleshooting items are listed in order of operation. OBSERVED PROBLEM When ignitor button is pressed and control knob is pressed in and turned to the PILOT position, there is no spark at ODS/pilot. When ignitor button is pressed and control knob is press in and turned to the PILOT position, there is a spark at ODS/pilot but no ignition.
  • Page 15: Troubleshooting

    OBSERVED PROBLEM B u r n e r ( s ) d o e s n o t l i g h t a f t e r ODS/pilot is lit. Delayed ignition of burner(s). Burner backfiring during combustion. Burner plaque(s) does not glow. Slight smoke or odor during initial operation.
  • Page 16 WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 17: Specifications

    8-1/8 EQUIPMENT SHUTOFF VALVE For all models. Equipment shutoff " valve with 1/8 NPT tap. FLOOR MOUNTING STAND Models ML060HPA,ML100HPA, ML100TPA For locating heater on the floor away from a wall. Complete installation instructions provided with floor mounting stand. ML100HPA...
  • Page 18 ILLUSTRATED PARTS BREAKDOWN ML060HPA...
  • Page 19: Parts List

    PARTS LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this ML060HPA manual. PART NUMBER MB10008 MB09003 ML006-02 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026-03 ML069-02 NV2020-12 ML073-01...
  • Page 20 ILLUSTRATED PARTS BREAKDOWN ML100HPA...
  • Page 21 PARTS LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this ML100HPA manual. PART NUMBER MB10008 MB09003 ML006-01 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026-02 ML069-02 NV2020-13 ML073-01 ML029-01 MB40033 MB40034...
  • Page 22 ILLUSTRATED PARTS BREAKDOWN ML100TPA...
  • Page 23 PART LIST This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page17 of this ML100TPA manual. PART NUMBER MB10007 MB09003 ML006-01 MB19006 ND1308x600x9 ND0803-6 ND0807-B2 ML026-02 ML069-02 845-4.8x60Z SIT544-000 ML111-02 ML056-03 MB40037...

This manual is also suitable for:

Ml100hpaMl100tpa

Table of Contents