(4) Detaching and refitting the heat roller separation claws
Follow the procedure below to replace the heat roller separation claws.
Procedure
1. Remove the fixing unit and separate the
fixing right unit and left unit (see pages 1-
6-43, 45).
2. Detach the fitting portions and then
remove the heat roller guide from the fix-
ing left unit.
3. Remove the heat roller separation claws
from the fixing left unit.
4. Replace the heat roller separation claws and
refit all the removed parts.
Heat roller guide
Heat roller separation claws
Fixing left unit
Figure 1-6-85
Fixing left unit
Figure 1-6-86
2FT
1-6-47