Kyocera KM-2550 Service Manual page 153

Hide thumbs Also See for KM-2550:
Table of Contents

Advertisement

Code
C6000
Broken fixing heater wire
The temperature does not become
°
°
100
C/212
F even if 30 s pass before
secondary stabilization.
When there is no 1
before secondary stabilization.
C6020
Abnormally high fixing unit ther-
mistor temperature
The fixing temperature exceeds 240
°
464
F for 40 ms.
C6050
Abnormally low fixing unit thermistor
temperature
The fixing temperature remains below
°
°
90
C/194
F for 1 s.
C6400
Zero-crossing signal problem
The engine PCB does not detect the
zero-crossing signal for the time speci-
fied below. At power-on: 3 s Others: 5 s
Contents
°
°
C/33.8
F rise in 5 s
°
C/
Causes
Check procedures/corrective measures
Poor contact in the
Reinsert the connector. Also check for conti-
thermistor connec-
nuity within the connector cable. If none,
tor terminals.
remedy or replace the cable.
Fixing thermistor
Check and reinstall if necessary.
installed incor-
rectly.
Fixing thermostat
Check for continuity. If none, replace the fix-
triggered.
ing thermostat.
Fixing heater M or
Check and reinstall if necessary.
S installed incor-
rectly.
Broken fixing
Check for continuity. If none, replace the fix-
heater M or S wire.
ing heater M or S.
Shorted thermistor. Measure the resistance. If it is 0 Ω, replace
the thermistor.
Broken heater con-
Replace the power supply PCB and check
trol circuit on the
for correct operation.
power supply PCB.
Poor contact in the
Reinsert the connector. Also check for conti-
thermistor connec-
nuity within the connector cable. If none,
tor terminals.
remedy or replace the cable.
Measure the resistance. If it is ∞ Ω, replace
Broken fixing ther-
mistor wire.
the fixing thermistor.
Fixing thermistor
Check and reinstall if necessary.
installed incor-
rectly.
Fixing thermostat
Check for continuity. If none, replace the fix-
triggered.
ing thermostat.
Fixing heater M or
Check and reinstall if necessary.
S installed incor-
rectly.
Broken fixing
Check for continuity. If none, replace the fix-
heater M or S wire.
ing heater M or S.
Poor contact in the
Reinsert the connector. Also check for conti-
connector termi-
nuity within the connector cable. If none,
nals.
remedy or replace the cable.
Defective power
Check if the zero-crossing signal is output
supply PCB.
from YC2-5 on the power supply PCB. If not,
replace the power supply PCB.
Defective engine
Replace the engine PCB if C6400 is
PCB.
detected while YC2-5 on the power supply
PCB outputs the zero-crossing signal.
Remarks
2FT-1
1-5-23