KYMCO Downtown 300i ABS Service Manual page 246

Table of Contents

Advertisement

20
.
EVAPORATIVE EMISSION CONTROL SYSTEM
PURGE CONTROL VALVE FLOW
INSPECTION
1. Connect a vacuum pump to the purge
control valve vacuum tube and apply
vacuum pressure of 45mm/Hg.
2. Connect a pressure pump to the tube that
goes to the charcoal canister and apply
pressure. The flow must be over 9.4 liters
per minute and replace the purge control
valve with a new one if the specified flow
is not reached.
To prevent damage to the purge control
valve, do not use high air pressure
sources. Use a hand operated pressure
pump only.
INSTALLATION
1. Install the purge control valve in the
reverse order of removal.
2. Route and reconnect the purge control
valve tubes properly and securely.
Be careful not to bend, twist or kink the
tubes during installation.
20-5
Downtown 300i ABS
Pressure Pump
Vacuum Pump