19. LIGHTS/METERS/SWITCHES
INSPECTION
Connect the fuel unit wire connectors and
turn the ignition switch "ON".
Before performing the following test,
operate the turn signals to determine that
the battery circuit is normal.
Measure
the
resistance
Red/Black and Green wire of the fuel unit
connector.
Standard (at 20°C/68°F):
Float at full position
Float at empty position About 100 Ω
between
the
About 1100 Ω
Downtown 300i ABS