Flow2 - Stairlift
F76
Battery needs charging
This error code appears after the lift has been placed on a charging contact
after code F21 has occurred (voltage <19V). The batteries have to be charged
to a minimum voltage of 25V by default and then the F76 will disappear.
Normal stop
Let the stair lift charge the batteries
Mode -3- / ELD mode
F77
Main motor temperature too high
The temp. of the main motor has risen to a critical level
Normal stop
Let cool down.
Mode -3-
F78
Level motor temperature too high
The temp. of the level motor has risen to a critical level
Normal stop
Let cool down.
Mode -3-
F83
Level sensors are off, but there's drive moment
Sensors are off while the drive is moving
Emergency stop / Stop level drive
Reboot the lift
Mode -3-