2015.04.16
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Flow2 - Stairlift
F53
Swivel position unknown
Reset point (zero opto) not "seen" (yet).
Normal stop
Find reset point using [E] button in mode -3-.
Mode -3- / ELD mode
F54
Data corrupt
Safety code is found to be incorrect.
Disable main drive / Stop level drive / Stop swivel drive
In mode -9- first clear rail data (Crd), than restore (rES). If this does not clear
the fault, the rail data have to be programmed manually.
--
F55
Brownout while moving
Power is switched off or fails during ride
Disable main drive / Stop level drive / Stop swivel drive
Check battery cable connection, fuse and measure voltage on battery
control board connector.
--
F63
Unexpected main motor movement
Main motor turns without user input (UI, RF, ELD, service buttons or
installation joystick.
Disable main drive
--
F64
Unexpected level motor movement
Level motor turns without user input (UI, RF, ELD, service buttons or
installation joystick.
Emergency stop / Stop level drive
--
F65
Unexpected swivel motor movement
Swivel motor turns without user input (UI, RF, ELD, service buttons or
installation joystick.
Emergency stop / Stop swivel drive
--
www.ThyssenKruppAccessibility.com