Access Flow2 User's Manual & Installation Instructions

Access Flow2 User's Manual & Installation Instructions

Communication module
Hide thumbs Also See for Flow2:

Advertisement

Quick Links

Flow2 - Communication Module
User Manual / Installation Instruction
Version 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Access Flow2

  • Page 1 Flow2 - Communication Module User Manual / Installation Instruction Version 1.0...
  • Page 2 © 2017 thyssenkrupp Stairlifts BV All rights reserved. Specifications and illustrations can be changed without prior notice. thyssenkrupp Stairlifts BV will not accept liability for any changes or typographic errors. Except for legal exceptions, this publication and/or its content may not be reproduced, copied and/or published by means of photocopies, films, electronic or any other form without the permission of thyssenkrupp Stairlifts BV.
  • Page 3: Table Of Contents

    Table of Contents General description ........................4 Use ............................5 Making a call........................5 Disconnecting ........................5 Choosing the next number..................... 6 Accepting incoming calls ....................6 Programming........................7 Required parts ........................7 Connecting the CM with the base station ..............7 Connection problems.......................
  • Page 4: General Description

    General description General description The Communication Module (hereafter CM) is an optional function. This option makes it possible to communicate via a landline with three pre-programmed telephone numbers. Incoming calls can also be accepted.
  • Page 5: Use

    The CM can be used to call three pre-programmed numbers. For example, in an emergency. The order in which these numbers are called can be configured. See Section 2. Making a call 4-7 s Press the yellow alarm button for 4 to 7 seconds. The dialling tone can now be heard. Release the alarm button.
  • Page 6: Choosing The Next Number

    Choosing the next number If the connection to the first contact does not succeed, you can choose to go to the next pre- programmed number. This is done as follows: Press the yellow alarm button briefly during the call once. The next number is now dialed. Note If the contact’s number redirects to voice mail, you must also briefly press the yellow alarm button once to call the next number.
  • Page 7: Programming

    Programming Programming To connect the CM to the landline, it must be connected to the base station of a DECT telephone. If a DECT telephone is already present, it can be used*. If this is not the case, a base station can be supplied by thyssenkrupp.
  • Page 8: Connection Problems

    Programming 2.3 Connection problems If, 2 minutes after turning on the lift and the CM, successful registration is not possible, one beep will be heard, the green light on the alarm button flashes briefly and the search is restarted. Possible solution 1: Check that the CM and the base station are connected to the mains supply and that they are switched on.
  • Page 9: Programming Options For The Cm

    Programming 2.4 Programming options for the CM The configuration of the CM must be done by dialling in. This is done by calling the landline number using the landline telephone* or a mobile phone. * To call an internal extension, consult the manual of the relevant DECT telephone. 2.5 Setting the CM in programming mode Code: ** #...
  • Page 10: Programming The Telephone Numbers

    Programming 2.6 Programming the telephone numbers *025*0*[telefoonnummer1]# *025*1*[telefoonnummer2]# *025*2*[telefoonnummer3]# Preferably, switch off the telephone microphone. Enter the following code on the telephone to put the CM in programming mode: **# Program the telephone numbers as follows: To program the first number, enter the following code: *025*0*[telephonenumber 1]# e.g.: *025*0*0101234567# To program the second number, enter the following code:...
  • Page 11: Testing The Cm

    Programming 2.9 Testing the CM If the CM is programmed, the following functions must be tested. (See Section 2) Accepting incoming calls Ending a call Calling pre-programmed telephone numbers. Note If the third number is the international emergency number, this must not be tested. 2.10 Restore factory settings of the CM There are 2 possible situations, check which situation applies: The CM is still connected to the old DECT base station.
  • Page 12: Error Codes

    Error codes Error codes LED colour Sound Cause Flashing red None Not connected to a base station or no base station selected. Flashing red Two short beep sounds, not CM power supply is lost or repeating. backup battery is charging. Flashing green Two beep sounds, repeating The CM tries to reconnect to...