4.1 Error and warning list

F01
Obstruction in current drive direction detected: left
F02
Obstruction in current drive direction detected: right
C04
Level beyond 2 degrees
F05
Level beyond 5 degrees
F06
Drive speed beyond track operating range
F07
Level beyond 7 degrees
F08
Level sensor deviation
F09
Hardware failure of the main drive
F10
Hardware failure of the level drive
F11
Hardware failure of the swivel drive
F12
Drive motor current trip or overvoltage occurred
F13
Level motor current trip or overvoltage occurred
F14
Swivel motor current trip or overvoltage occurred
F15
HALL sensor failure of the main drive
F16
HALL sensor failure of the level drive
F17
HALL sensor failure of the swivel drive
F18
Drive speed beyond maximum limit
F19
Drive speed beyond ELD operating range
F20
Software inconsistency detected (assert)
F21
Battery voltage low while moving up
F22
Battery failure: under or overvoltage detected
F23
Brake circuit failure detected
F24
HW Error detected
F25
Wrong HW/SW combination
Reduce speed failed
F26
Normal stop failed
F27
Emergency stop failed
F28
Disable drive main failed
F29
Stop drive level failed
F30
Stop drive swivel failed
F31
F32
User emergency stop
F33
Overspeed (OSG) tripped
F34
Level sensor failure
F35
Level sensor failure
F36
Level sensor failure
F37
Swivel position outside operating range (+/- 110 deg)
F40
OSG opto failure
F41
ELD opto failure
F42
Swivel zero opto failure
F47
Swivel squeeze opto failure
F49
RF unit is not responding
F50
Failed to read parameters (motor control or application)
F51
Failed to read the track data
F52
Drive position is found to be incorrect
Flow2 - Stairlift
F53
Swivel position is found to be incorrect
F54
Safety code is found to be incorrect
F55
Brownout is triggered while moving
C56
An unexpected negative contact was detected
C58
A negative contact was expected but not detected
C60
The track position value is beyond the maximum track length
C61
The swivel sync opto 0 is detected at an unexpected swivel position
C62
The swivel sync opto has an inverted value
F63
Main drive moment detected without user input
F64
Level drive moment detected without user input
F65
Swivel drive moment detected without user input
F66
Wrong direction detected for main drive
F67
Wrong direction detected for level drive
F68
Wrong direction detected for swivel drive
F69
CPU startup check fails (includes code CRC check)
C70
Lift driving in normal mode without test run performed
C71
User emergency maintenance counter elapsed
F72
User emergency maintenance counter elapsed
C73
Position outside track bounds
F74
Manual swivel not in position while starting
F75
Battery voltage below upwards level
F76
Battery voltage recharge required
F77
Drive I²T critical Main
F78
Drive I²T critical Level
C80
Drive I²T warning Main
C81
Drive I²T warning Level
Level sensors are off, but there's drive moment (allowed in service
F83
because of mode -3-)
C85
Backup battery low (below 1.65V)
C86
Level sensor deviation > 4 degrees
C87
Swivel deviation > 10 degrees
S1
HW release circuit failure
S2
Swivel current measurement too low
S3
Swivel current offset calibration failed
S4
Level current offset calibration failed
S5
Drive current offset calibration failed
S6
+15V outside of limits
S7
+5V outside of limits
S8
Reference voltage outside of limits
S9
+3V3 overload
S10
MCU internal failure
S11
Check timeout
S12
Supply enable/disable circuit failure
S13
Main/Level/Swivel overcurrent protection failure
www.ThyssenKruppAccessibility.com
Tab 06: Systematic fault finding