Flow2 - Stairlift
F66
Wrong main motor direction
Detected running direction of main motor is incorrect
Disable main drive
--
F67
Wrong level motor direction
Detected running direction of level motor is incorrect
Emergency stop / Stop level drive
--
F68
Wrong swivel motor direction
Detected running direction of swivel motor is incorrect
Emergency stop / Stop swivel drive
--
F69
CPU runtime check failure
Processor startup check fails
Disable main drive / Stop level drive / Stop swivel drive
Reboot
--
F72
Test user emergency stop required
Maintenance timer has expired
Normal stop
Joystick from User Interface has to be removed and re-inserted
Mode -3-
F74
Manual swivel turned.
Swivel has been unlocked and turned.
Normal stop
Turn swivel in normal ride position and lock before starting.
Mode -3-
F75
Battery voltage low
If battery voltage is below 21V the lift won't drive up from halt position. It is
still possible to drive down.
Normal stop
Leave lift at charging station until battery is sufficiently charged.
Mode -3- / ELD mode