Access Flow2 Manual page 19

Table of Contents

Advertisement

2015.04.16
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Error code
Error message
Description
Safety action
Possible solution
Error suppressed in
Flow2 - Stairlift
F41
Opto failure ELD
Defective opto emergency lowering device
Normal stop
Replace opto
Mode -3-
F42
Opto failure swivel zero
Defective opto swivel zero
Normal stop
Replace opto
Mode -3- / ELD mode
F47
Opto failure squeeze
Defective squeeze opto
Normal stop
Replace opto
Mode -3- / ELD mode
F49
Receiver board failure
Defective receiver board
Normal stop
-
Check cable and connections and receiverboard version.
Replace if damaged.
-
Replace receiver board
Mode -3- / ELD mode
F50
Parameters corrupt
Failed to read parameters (motor control or application)
Normal stop
Reboot / Mode -9- CLR, please note to backup your raildata.
Mode -3-
F51
Rail data corrupt
For example: less than 2 halt positions or speed entries programmed
Normal stop
Program correctly or restore by Mode -9- (RES)
Mode -3- / ELD mode
F52
Drive position unknown
Reset point not "seen" (yet).
Normal stop
Drive to reset point in mode -3-
Mode -3- / ELD mode