Auto Scan
Manual Operation in Override Mode
If the PLC is not connected to the M12, the table or hop-
per may be turned on manually by holding the power
key for 1.5 seconds. This will start the override operation
and the table or hopper will turn on. To turn off the table
or hopper, press the power key again.
Auto Scan
NOTE: Auto scan should be used to ensure proper
repair/assembly was performed on the table. For opti-
mal part movement, the frequency should be manually
set.
Perform Auto Scan
Table
1. Confirm no parts are on the table or in the hopper.
2. Ensure no person or thing is touching the unit.
3. Press main power switch to the ON position.
ti21993a
4. On the TABLE CONTROL TOUCH PAD, press and
hold the ENTER key to access the main menu.
5. Press DOWN ARROW to select the Frequency sub-
menu and press the ENTER key.
6. Press the UP ARROW three times to select Auto
Scan from the menu.
7. Press the ENTER key to perform an Auto Scan.
8. The table will cycle through different amplitudes and
frequency for about 15 seconds until the resonate
frequency has been found. If the resonate fre-
quency cannot be found, see Troubleshooting,
page 26.
14
NOTE: The table and hopper were Auto Scanned at
manufacture. The serial label above the Control Display
(Fn) lists the natural frequency of the table and hopper
when the G-Flex 1500 was manufactured. The frequen-
cies from Step 9 (Table) and Step 1 (Hopper) should be
close to the frequencies on the serial label.
9. Confirm the resonate frequency is between 60-67
Hz. If it falls outside of this range, see Trouble-
shooting, page 26.
10. Press the POWER key on the TABLE CONTROL
TOUCH PAD to turn the part table OFF.
Hopper
1. Repeat the Auto Scan procedure for the hopper
using the HOPPER CONTROL TOUCH PAD. The
resonate frequency for the hopper should be
between 70-95 Hz.
2. Press the POWER key on the HOPPER CONTROL
TOUCH PAD to turn the hopper OFF.
For a detailed explanation on all control settings, see
Detailed Control Adjustment, page 15.
ti21921a
332462E